GAGGIA BABILA
RINSE
When performed
No. of Pulses
Stop option
Can be disabled by the user
Can be disabled by
the Production/Service Dept
No. of pulses adjustable by
the user
No. of pulses adjustable by
the Production/Service Dept
Pulse range
(Min - Max)
Input time (min - max)
Input time (default)
Input time set by user
Input time set by
the Production/Service Dept
Boiler temperature during Stand-by
Cup heater during stand-by
Timer and Stand-by
** The machine switches on at the TimerOn (Timer) value and switches off when the
"Stand-by input time" (Delay - Time) has elapsed
DREG DRAWER
Time-out for dreg drawer
Warning to empty dreg drawer
Empty dreg drawer block alarm
(double expresso as the last dispensed product)
Reset dreg counter
When the machine is switched on
and the temperature of the
boiler reaches ≤ 50°C
Yes, by pressing any key
STAND-BY
Initial rinse
130
Yes
No
No
No
No
Only if the Warning or the empty dreg drawer
alarm is triggered and the dreg drawer is re-
02 TECHNICAL SPECIFICATIONS
Final rinse
When the machine is switched
off electronically, manually or
automatically after 60', if at least
one coffee has been dispensed
before being switched off
100
Yes, by pressing any key
No
No
No
No
No
Description and values
15 minutes - 180 minutes
15 minutes
Yes
Yes
Boiler OFF
Cup heater OFF
Yes **
Description and values
5 sec.
Yes, after 12 lots of dregs
15 lots of dregs
(16 lots of dregs)
moved for at least 5 seconds.
2/6