Carrier X-Power VRF series Owner's Manual

Carrier X-Power VRF series Owner's Manual

Full dc inverter outdoor unit

Advertisement

OWNER'S
MANUAL
FULL DC INVERTER XPOWER VRF OUTDOOR UNIT
Thank you for purchasing this air conditioner.
Before using it, please read this manual and keep it for future reference.
Caution:The heating function of an indoor unit is available only when it is connected to
a cooling & heating outdoor unit.

Advertisement

Table of Contents
loading

Summary of Contents for Carrier X-Power VRF series

  • Page 1 OWNER'S MANUAL FULL DC INVERTER XPOWER VRF OUTDOOR UNIT Thank you for purchasing this air conditioner. Before using it, please read this manual and keep it for future reference. Caution:The heating function of an indoor unit is available only when it is connected to a cooling &...
  • Page 3: Table Of Contents

    Never inspect or service the unit yourself. CONTENTS PAGE Ask a professional for help. IMPORTANT SAFETY INFORMATION............ Do not dispose this product as unsorted waste. It must PART NAMES..................be separately collected and processed. OPERATION AND PERFORMANCE............Do not dispose of electrical appliances as unsorted FAULTS AND CAUSES...............
  • Page 4: Part Names

    Power the unit off before cleaning it to avoid electric 2. PARTS NAMES shocks. Install an earth leak detector to avoid electric shocks and fires. Ensure the air conditioner is grounded. To avoid electric shocks, ensure the unit is grounded and that the earth wire is not connected to a gas or water pipe, lightning conductor, or telephone earth wire.
  • Page 5: Faults And Causes

    4. If you set the unit to only respond to the Heating mode, the indoor Protection Device unit will run normally if it is running in Heating mode, but it will This protection device will stop the unit automatically if the air display Mode Conflict if it is running in Cooling or Fan mode.
  • Page 6 Please view the following illustrations (before servicing) Table.4-1 Troubles Causes Outdoor unit FAN function stop automatically to defrost is Mist or water accompanied by the starting and stopping sound of the solenoid valve. The unit hisses At the beginning and end of the running process, it sounds like water is flowing in the valve for 3-15 minutes due to the dehumidifying process of the refrigerant current.
  • Page 7: Malfunctions

    5. MALFUNCTION Malfunction display of outdoor unit’s DSP1 Table.5-1 Error or protection type Note Error code Outdoor unit COMM.Error Only display in slave unit Phase protection Twenty minutes after the first power on or indoor COMM.Error with indoor unit and outdoor communication break off after 2 minutes when the unit has been running for 20 minutes Reserve Outdoor temp.
  • Page 8: Constraint Cooling And Queries

    6. CONSTRAINT COOLING AND QUERY MAIN BOARD (OUTDOOR UNIT) Constraint cooling button Constraint Cooling Once pressing the constraint cooling button (see the chart on Query button the right), all indoor units will be on forced cooling mode and the wind speed is HIGH). COOL CHECK Usage application of the SW2 spot check...
  • Page 9: Customer Details

    8. CUSTOMER DETAILS Branch Address …………………………………………………………… …………………………………………………………… …………………………………………………………… Telephone …………………………………………………………… Person to be contacted …………………………………………………………… Dealer address …………………………………………………………… …………………………………………………………… …………………………………………………………… Telephone …………………………………………………………… Person to be contacted …………………………………………………………… …………………………………………………………… Signature of the Dealer with Seal. In all correspondence/communication state your name, address, the serial number of your air conditioning unit, date of purchase and dealer’s name (include address), location of unit and description of problem, for prompt and immediate attention Name of Customer...