Example Removal of Factory-Built Fireplace Cont.
Keep sharp edge of
metal floor away from
power cord
Figure 11.1. Place the insert into the facto-
ry-built firebox. Ensure that the power cord
can not be damaged by the sharp metal
edge. You may need to cut out a notch to
accommodate the cord.
Leveling Leg
Figure 11.2. Ensure that the leveling leg is
positioned over the 2 x 4 before leveling the
insert. Minimum 1" clearance.
E. Installation into a Masonry Fireplace
All modifications that can be made to a Factory Built Fire-
place can be made to a Masonry Fireplace.
In addition DO NOT remove any brick or mortar from the
existing fireplace.
WARNING
Removing floor of fireplace must not weaken structure
of firebox or reduce protection for combustible materials.
Final approval of this installation type is contingent upon
the appropriate local authority having jurisdiction.
June 5, 2017
F. Prefabricated Metal Chimney
The chimney can be new or existing, masonry or prefabricated
and must meet the following minimum requirements:
• M ust be minimum 6 inch (152mm) inside diameter of
high temperature chimney listed to UL 103 HT (2100
or ULC-S628.
• M ust use components required by the manufacturer for
installation.
• M ust maintain clearances required by the manufacturer
for installation.
• R efer to manufacturers instructions for installation
•This insert is listed to ASTM E 1509-12 Standard and
is approved for installation into listed factory-built zero
clearance fireplaces listed to UL 127 conforming to the
following specifications and instructions:
•The original factory-built clearance fireplace chimney
cap must be re-installed after installing the approved
chimney liner meeting type UL 103 HT requirements
(2100°F) per UL 1777.
•If the chimney is not listed as meeting HT requirements,
or if the factory built fireplace was tested prior to 1998, a
full height listed chimney liner must be installed from the
appliance flue collar to the chimney top.
1"
•The liner must be securely attached to the insert flue collar
and the chimney top.
•The air flow of the factory-built zero-clearance fireplace
system must not be altered. The flue liner top support
attachment must not reduce the air flow for the existing
air-cooled chimney system.
•No dilution air is allowed to enter the chimney.
1. Secure the fireplace damper in the open position. If
this cannot be accomplished, it will be necessary to
remove the damper
2. Seal damper area of chimney around chimney
connector with a high temperature sealant or seal
insert against the face of the fireplace.
3. Both methods must be removable and replaceable
for cleaning and re-installation.
Risk of Fire!
Follow venting manufacturer's clearances and
instructions when installing venting system.
NOTICE: In Canada when using a factory-built chim-
ney it must be safety listed, Type UL103 HT (2100
o
[1149
C] CLASS "A" or conforming to CAN/ULC-
S629M, STANDARD FOR 650
CHIMNEYS.
7019-230G
Santa Fe Pellet Insert
WARNING
o
C FACTORY-BUILT
o
F)
o
F)
11