Alignment
VOX O
L
N
EVEL
This parameter is to align the "VOX On Level".
Set the Sensitivity of the VOX circuitry's input audio detector.
1. Press the "VOX ON Level" button to start the
alignment.
The VOX ON Level window will appear.
2. Then input the alignment value in the "New" box.
Default: 80
Input Range: 0 (Level Down) ~ 255 (Level Up)
3. Click the "OK" button, the data will be saved and
the alignment is complete.
TX MSK L
EVEL
This parameter is to align the modulation level of the ANI function.
1. Press the "TX MSK" button to start the alignment.
The TX MSK Level window will appear.
2. Then input the alignment value in the "New" box.
Default: 9
Input Range: 0 (Level Down) ~ 15 (Level Up)
3. Click the "OK" button, the data will be saved and
the alignment is complete.