Advertisement

TO START ENGINE WITH A WEAK BATTERY
(See Fig. 24)
CAUTION: Lead-acid batteries generate
explosive gases. Keep sparks, flame
and smoking materials away from bat-
teries. Always wear eye protection when
around batteries.
If your battery is too weak to start the engine, it should be
recharged. (See "BATTERY" in the Customer Responsibili-
ties section of this manual).
If "jumper cables" are used for emergency starting, follow
this procedure:
IMPORTANT: YOUR TRACTOR IS EQUIPPED WITH A 12
VOLT NEGATIVE GROUNDED SYSTEM. THE OTHER
VEHICLE MUST ALSO BE A 12 VOLT NEGATIVE
GROUNDED SYSTEM. DO NOT USE YOUR TRACTOR
BATTERY TO START OTHER VEHICLES.
TO ATTACH JUMPER CABLES -
Connect each end of the RED cable to the POSITIVE (+)
terminal of each battery, taking care not to short against
chassis.
Connect one end of the BLACK cable to the NEGATIVE
(-) terminal of fully charged battery.
Connect the other end of the BLACK cable to good
CHASSIS GROUND, away from fuel tank and battery.
TO REMOVE CABLES, REVERSE ORDER -
BLACK cable first from chassis and then from the fully
charged battery.
RED cable last from both batteries.
POSITIVE TERMINAL
CHASSIS
POSITIVE
TERMINAL
SERVICE AND ADJUSTMENTS
NEGATIVE TERMINAL
CABLES
NEGATIVE
TERMINAL
CHARGED
BATTERY
FIG. 24
REPLACING BATTERY (See Figs. 25 and 26)
CAUTION: Do not short battery
terminals by allowing a wrench or any
other object to contact both terminals
at the same time. Before connecting
battery, remove metal bracelets,
wristwatch bands, rings, etc.
Positive terminal must be connected
first to prevent sparking from acciden-
tal grounding.
Lift seat pan to raised position.
Disconnect BLACK battery cable first then RED battery
cable and carefully remove battery from tractor.
Install new battery with terminals in same position as old
battery.
First connect RED battery cable to positive (+) terminal
with hex bolt and keps nut as shown. Tighten securely.
Slide terminal cover over terminal.
Connect BLACK grounding cable to negative (-) terminal
with remaining hex bolt and keps nut. Tighten securely.
SEAT PAN
TERMINAL
COVER
POSITIVE
(RED) CABLE
22
FIG. 25
KEPS
NUT
NEGATIVE
(BLACK) CABLE
FIG. 26
HEX
BOLT