Fisher & Paykel RS9120W User Manual page 37

Activesmart integrated refrigerator
Hide thumbs Also See for RS9120W:
Table of Contents

Advertisement

Ice & Water model only
PROBLEM
Water has poor
taste/odour.
Water dispenser
does not work.
Water in first
glass is warm.
Drips overflow
drip tray.
Water flow rate
has slowed down.
TROUBLESHOOTING
POSSIBLE CAUSES
Refrigerator not used for an
extended period.
Water supply turned off or
not connected.
Supply line may be blocked.
On first installation there
may be air in water system.
Filter may be blocked and
needs replacing.
Water frozen in tank.
Water dispenser not used
for extended period.
Tank capacity used recently.
Air trapped in tank.
New filter installed.
Filter cartridge is restricted.
Check if filter icon is
illuminating.
WHAT TO DO
Flush the water filtration system.
Dispense and discard 4L of water,
this will ensure the water tank is
refilled with fresh water.
Turn water on.
Check supply for kinks or leaks.
To remove air, run 4L of water
through the dispenser.
Replace filter (product parts and
accessories can be purchased
through our Customer Care Centre.
Increase temperature to a warmer
setting in fresh food compartment
and freezer.
Discard first glass of water
dispensed.
Allow water time to cool.
Flush the water filtration system.
Dispense and discard 4L of water,
then rest the dispenser pad for a
further 2 minutes.
Dispense and discard a further 4L of
water. This will displace trapped air
in the water tank and filter system.
Replace filter cartridge (product
parts and accessories can be
purchased through our Customer
Care Centre.
35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rs9120wu

Table of Contents