Baxi RC 06 Instructions Manual

Baxi RC 06 Instructions Manual

For baxi luna 3 comfort

Advertisement

RC 06
it - Istruzioni TELECONTROLLO
en - Remote controller instruction
hu - Utasítás TÁVVEZÉRLÉS
ru - Руководство по эксплуатации
pl - Instrukcja obsługi

Advertisement

Table of Contents
loading

Summary of Contents for Baxi RC 06

  • Page 1 RC 06 it - Istruzioni TELECONTROLLO en - Remote controller instruction hu - Utasítás TÁVVEZÉRLÉS ru - Руководство по эксплуатации pl - Instrukcja obsługi...
  • Page 2 1. Commissioning of the boiler 2. Special functions 3. Error messages and table of faults 4. Parameters display 5. Kreg climatic curves 6. Parameters setting Figure 1 0609_1902 71.09161.01...
  • Page 3 DESCRIPTION FUNCTION BUTTON Information/Programming button Timing function Central Heating temperature regulation Con rmation button Setting programmed operation in heating mode Manual/Automatic/Off Economy-Comfort button Enabling Summer-Winter-Heating only-Off Domestic Hot Water temperature regulation DESCRIPTION SYMBOL DISPLAY Time switch program histogram Comfort setpoint temperature mode Reduced setpoint temperature mode Communication with the gas boiler in progress Modulating ame level (boiler power level)
  • Page 4 SYMBOL MEANING There are 4 power levels displayed during boiler operation, relevant to the gas boiler modulation, as shown in g. 2: Figure 2 1.2 DESCRIPTION OF BUTTON (Summer - Winter - Heating only - Off) Press this button to set the following boiler operation modes: mode the symbol is shown on the display.
  • Page 5 mode the symbols are shown on the display. The boiler meets DHW and heating mode demands (frost protection function activated). mode the symbol is shown on the display. The boi- ler only meets heating mode demands (frost protection function is enable). is selected, neither of the two symbols ( ) is displayed.
  • Page 6 1.4 ROOM AND DOMESTIC HOT WATER (D.H.W.) TEMPERATURE ADJUSTMENT The room ( ) and D.H.W. ( pressing the relative +/- buttons ( gure 1). When the burner is lighted the display shows the symbol ( ) as described in section 1.1. During a CH mode, the display shows a CH ( ) symbol and the room tem- perature value (°C).
  • Page 7 1.5 PROGRAMMING (PROGR) Press the button: the display shows (brie y) the message and the time starts ashing. Note: If no button is pressed the function ends automatically after approx. 1 minute. to set the day of the week “ ”...
  • Page 8 On 1 Of 1 On 2 Of 2 On 3 Of 3 On 4 Of 4 (monday) (tuesday) (wednesday) (thursday) 06:00 08:00 11:00 13:00 17:00 23:00 24:00 24:00 (friday) (saturday) (sunday) To set a single time band, proceed as follows: 1) Press the button and then the button...
  • Page 9 By setting the lighting time equal to the switching off time time band is cancelled and the program goes to the next time slot. (ex. =09:00 - =09:00 the programme “skips” time band 1 and continues with …). 71.09161.01...
  • Page 10 This function enables the programming of 4 common boiler activation and deactivation time slots for several days or the entire week (see the summary table below). To set a single time band, proceed as follows: 1) Press the button and then the button 2) Select a GROUP of days by repeatedly pressing the buttons +/- 3) press the 4) repeat the operations described in points 4-10 of paragraph 1.6.1.
  • Page 11 1.7 PROGRAMMING DHW MODE OPERATION TIMES This function enables the programming of four boiler DHW mode operation time slots in the span of a week (the programmed time slots are the same for every day of the week). To set the programming of DHW mode operation times, proceed as follows:...
  • Page 12 71.09161.01...
  • Page 13 2. SPECIAL FUNCTIONS 2.1 ECONOMY - COMFORT FUNCTION This function enables the user to set two different room temperature setpoints: For more simplicity it’s better to set the COMFORT value temperature higher than the ECONOMY value temperature. To set the required room temperature, press the button: ”...
  • Page 14 2.2 SHOWER FUNCTION The shower function ensures better hot water comfort, e.g. during a shower. This function enables domestic hot water to be drawn at a lower temperature than the nominal temperature value. To set or modify the max. shower function temperature value, refer to section 2.3. This function can be manually activated in the following way: and then the button (the message...
  • Page 15 2.4 PROGRAMMABLE SWITCHING TIME FUNCTION (BUTTON ) It is possible to temporary shut off the timing program (section 1.6) for a cer- tain period of time. During this period of time a minimum room temperature value is guaranteed (default value 5°C). To modify this temperature value see section 2.3 under the entry “...
  • Page 16 Press the +/- buttons to set the period of the timing program with 10 minutes step. The period of time is settable from a minimum of 10 minutes to a maximum of 45 days. By pressing the + button after , the display shows “...
  • Page 17 3. ERROR MESSAGES AND TABLE OF FAULTS There are two type of fault carried out by the temperature control: FAULT and BLOCK. FAULT If a fault occurs, the display shows the symbols ashing together with the writing. The fault is identi ed by an error code followed by letter and is not resettable.
  • Page 18 Press the button ( gure 1) for at least 2 seconds. Gas supply fault If this fault persist, call an authorised Service centre. Press the button ( gure 1) for at least 2 seconds. Safety thermostat sensor tripped If this fault persist, call an authorised Service centre. Flue pressure switch tripped Call an authorised Service centre.
  • Page 19 4. PARAMETERS DISPLAY 4.1 INFORMATION AND ADVANCED SETTING MODE To access the Information and Advanced Setting mode, it is necessary to press, for at least 3 seconds, the To escape the INFO mode brie y press the button. In this mode press the button.
  • Page 20 D.H.W. ow temperature. Maximum setpoint temperature value setting. Press the +/- buttons to set the value. Maximum D.H.W. temperature setpoint (max. settable value). Minimum D.H.W. temperature setpoint (min. settable value). Power level/modulating ame (%). Water pressure heating circuit (bar). Water ow rate (l/min). Central Heating setting constant (0,5...9,0 - factory setting 3 - Refer to section 5 - Graph 1).
  • Page 21 Room temperature in uence Enabled/Disabled (1/0). Factory setting 1. In this case, the rooms temperature regulation it depends on the ow temperature set (“CH SL”). Press +/- buttons to set the value. Reading correction of the remote control Room Sensor (factory setting 0.0°C).
  • Page 22 Enabling the DHW programmer (only for boilers connected to an external hot water tank). Factory setting 1. Frost protection Enabled/Disabled (1/0). Factory setting 1. this value must be always enable (1). Summer temperature control Enable/Disable (factory set = 0). By setting this parameter = 1 the function is enabled and a new boiler opera- tion mode “SUMMER+COOL”...
  • Page 23 ow temperature (°C) external temperature (°C) 71.09161.01...
  • Page 24 6. PARAMETERS SETTING To access the Parameters setting mode proceed as follows: button then press together the button. When the function is activated, the display shows “F01” with the value of the selected parameter. the value is automatic saved after about 3 seconds. (Do not press any button until the value is beginning to ash again).

Table of Contents