Gravity Centre; Location And Assembling; Location Designation; Sound Level - Carrier 48EN Installation, Operation And Maintenance Instructions

Packaged rooftop cooling only / heat pumps with integrated gas burner
Table of Contents

Advertisement

Packaged rooftop units
with integrated gas burner

Gravity centre

Z
X
Y
Centre of gravity (mm)
48EN/EH
Assembly
X
MO
1062
241
MS
1127
MA / MC0
1193
MO
1062
321
MS
1127
MA / MC0
1193
MO
1062
361
MS
1127
MA / MC0
1193
MO
1100
242
MS
1165
MA / MC0
1223
MO
1100
322
MS
1165
MA / MC0
1223
MO
1100
362
MS
1165
MA / MC0
1223
M0
1024
420
MS
1085
MA / MC0
1186
M0
1024
485
MS
1085
MA / MC0
1186
M0
1024
540
MS
1085
MA / MC0
1186
M0
1024
600
MS
1085
MA / MC0
1186
The unit weight includes the burner installed as standard which matches the
heaviest one amongst those available.
Weight
(kg)
Y
Z
1310
830
1497
1355
832
1578
1385
804
1705
1310
830
1581
1355
832
1662
1385
804
1789
1310
830
1717
1355
832
1798
1385
804
1925
1300
845
1723
1345
847
1805
1386
776
1925
1300
845
1806
1345
847
1888
1386
776
2008
1300
845
1942
1345
847
2024
1386
776
2144
2300
794
2360
2353
804
2458
2469
746
2724
2300
794
2402
2353
804
2500
2469
746
2766
2300
794
2459
2353
804
2557
2469
746
2823
2300
794
2512
2353
804
2610
2469
746
2876
6. L
OCATION AND ASSEMBLING

Location designation

Before moving the unit, make sure that all panels are fastened in place.
Lift and lower with care.
When choosing the location, in any way the selected fashion, the
following precautions have to be taken into consideration:
- It is mandatory to comply with norm EN 378-3 on Safety and
Environmental Requirements. Part 3: "In situ" installation and
protection to people.
- The area where the unit will be located must be perfectly accessible
for cleaning and maintenance operations (check minimum free space
for maintenance). Leave enough space for air circulation around the
unit.
- Foresee appropriate damping devices throughout the installation to
ensure that noise and vibration transmission is avoided (refer to the
section "Anti-vibration Anchoring").
- Check that the structure can withstand the weight of the unit.
- Since the unit is designed to work outdoors, some specifi c installation
norms must be followed:
• The unit will be located on the roof of the premises. If it is foreseen
that it will work more on heating than on cooling, it is preferable to
direct the coil towards the sun. If little work on heating is foreseen,
choose North direction.
• Avoid placing obstacles in the air outlet or return. No obstacle may
impede the air aspiration into the coils. Do not fi x the outdoor coil
side in the predominant wind direction.
• Do not install the unit in a closed enclosure or in conditions that
originate air recirculation.
• The chosen location must not fl ood and must be above the average
height the snow reaches in that region.
• All models can be installed on the fl oor or on a brick frame or steel
profi le (see optional preassembly frames in chapter 11). In any
case, check that the unit is perfectly level.

Sound Level

These units are designed to work with a low acoustic level. In any case,
in the design of the installation the outdoor environment, the kind of
building for the noise transmitted in the air and the solid elements for the
vibration transmission must be taken into consideration for the acoustic
radiation. If necessary, commission a study by an acoustic technician.
Sound power level

48EN/EH
241
321
361
Total dB(A)
90
90
91
Note: The sound power spectrums can be consulted in the technical brochure
for the 48EN/EH series.
Sound pressure level

Measurement conditions: in free fi eld, measured at a distance of 5
metres, directivity 2 and at 1.5 metres from the ground.
48EN/EH
241
321
361
Total dB(A)
63
63
64
Note: The sound pressure level depends on the installation conditions and, as such,
it only indicated as a guide. Values obtained according to the ISO 3744 standard.
242
322
362
420 485 540 600
88
88
89
94
95
95
242
322
362
420 485 540 600
61
61
62
67
67
67
95
67
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

48eh

Table of Contents