PROBLEM
Motor will not run.
CAUSE
Fuse
blown,
breaker tripped.
Extension cord is wrong
length or gauge.
Loose
electrical
connections.
Faulty motor.
Motor overload protection
switch has tripped
19 - ENG
CORRECTION
circuit
Check fuse box
for blown fuse and
replace as necessary.
Reset circuit breaker.
Do not use a fuse or
circuit breaker with
higher rating than
that specified for your
particular branch circuit.
Check for proper
fuse. You should use
a time delay fuse.
Check for low
voltage problem.
Check the
extension cord.
Disconnect the other
electrical appliances
from circuit or operate
the compressor on its
own branch circuit.
Check the
extension cord.
Check wiring connection
inside terminal box.
Have checked by
a Trained Service
Technician.
Refer to "Motor Overload
Protection" under
Operation. If motor
overload protection
trips frequently,
contact a Trained
Service Technician
1000003754