Heating Capacity - Fujitsu AR*C45LCTU series Technical Manual

Duct type
Table of Contents

Advertisement

6-2.

HEATING CAPACITY

MODEL
: ARC45LC
AFR
55.8
°CDB
°CDB
°CWB
-15
-10
-5
0
5
7
10
15
20
24
MODEL
: ARC54LC
AFR
55.8
°CDB
°CDB
°CWB
-15
-10
-5
0
5
7
10
15
20
24
3
AFR: Air flow rate ( m
/min)
TC : Total capacity (kW)
IP : Input power (kW)
16
TC
IP
-16
11.47
4.69
11.19
-11
12.63
4.70
12.33
-7
13.99
4.70
13.65
-2
15.28
4.70
14.91
3
16.36
4.70
15.97
6
17.01
4.70
16.61
8
18.16
4.70
17.73
10
18.03
4.22
17.60
15
18.59
4.22
18.14
18
18.50
3.81
18.06
16
TC
IP
-16
12.10
4.92
11.81
-11
13.42
5.07
13.10
-7
15.02
5.07
14.66
-2
16.24
5.07
15.86
3
17.43
5.07
17.02
6
18.90
5.07
18.45
8
19.20
5.07
18.75
10
18.03
4.22
17.60
15
18.59
4.22
18.14
18
18.50
3.81
18.06
Indoor temperature
18
20
TC
IP
TC
IP
4.79
10.92
4.89
4.80
12.03
4.90
4.80
13.32
4.90
4.80
14.55
4.90
4.80
15.58
4.90
4.80
16.20
4.90
4.80
17.30
4.90
4.31
17.17
4.40
4.31
17.70
4.40
3.89
17.62
3.97
Indoor temperature
18
20
TC
IP
TC
IP
5.03
11.52
5.13
5.17
12.78
5.28
5.17
14.30
5.28
5.17
15.47
5.28
5.17
16.60
5.28
5.17
18.00
5.28
5.17
18.29
5.28
4.31
17.17
4.40
4.31
17.70
4.40
3.89
17.62
3.97
- (01 - 13) -
22
24
TC
IP
TC
IP
10.65
4.90
10.37
4.90
11.73
4.90
11.43
4.90
12.99
4.90
12.65
4.90
14.19
4.90
13.82
4.90
15.19
4.90
14.80
4.90
15.80
4.90
15.39
4.90
16.86
4.90
16.43
4.90
16.74
4.40
16.31
4.40
17.26
4.40
16.82
4.40
17.18
3.97
16.74
3.97
22
24
TC
IP
TC
IP
11.23
5.23
10.94
5.28
12.46
5.28
12.14
5.28
13.94
5.28
13.59
5.28
15.08
5.28
14.70
5.28
16.19
5.28
15.77
5.28
17.55
5.28
17.10
5.28
17.83
5.28
17.38
5.28
16.74
4.40
16.31
4.40
17.26
4.40
16.82
4.40
17.18
3.97
16.74
3.97

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ar*c54lctu seriesAo*a45lctl seriesAo*a54lctl series

Table of Contents