Soleus Air DMG-135-60 Operating Instructions Manual

Soleus Air DMG-135-60 Operating Instructions Manual

Commercial low grain refrigerant dehumidifier

Advertisement

Model Number:
DMG-135-60
5008441
V.170405

Advertisement

Table of Contents
loading

Summary of Contents for Soleus Air DMG-135-60

  • Page 1 Model Number: DMG-135-60 5008441 V.170405...
  • Page 2: Purchase Information

    Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new Soleus Air Dehumidifier. For your own records, please attach a copy of your sales receipt to this manual. Also, write the...
  • Page 3 DEHUMIDIFIER INFORMATION RECOMMENDED HUMIDITY LEVELS • Spring/Summer: 30% - 50% • Fall/Winter: 35% - 55% • RestorationWork: Continuous “CO” Operation WARM AIR EXHAUST IS NORMAL During operation your dehumidifier will exhaust warm air from the side of the unit. This is normal operation. LESS MOISTURE BEING REMOVED OVER TIME IS A GOOD THING! Using a dehumidifier will cause your area to maintain a more comfortable humidity level.
  • Page 4: Package Contents

    (1) Commercial Low Grain Refrigerant Dehumidifier (1) Operating Instructions (1) Pump Drain Hose (19 Feet) (1) Power Cord (25 Feet) SPECIFICATIONS Model Number DMG-135-60 135 Pints per day (AHAM) Dehumidifying Capacity 220 Pints per day (At Saturation) Power Consumption (Watts) 1100 Watts...
  • Page 5: Product Features

    PRODUCT FEATURES Removes up to 135 pints at AHAM / 220 Pints At Saturation of moisture from the air every 24 hours. Adjustable humidistat from 30%-90% for precise humidity con- trol. Dual Floor Fan exhausts air over surface area for a faster dry time.
  • Page 6: Product Setup

    PRODUCT SETUP 1) Adjustable Handle: The handle can adjusted to different heights using the included Handle Knobs. Screw in the Handle Knobs on either side of the handle to secure the handle at the customized height. 2) Automatic Draining: Insert the included 19 foot Drain Tube onto the Drain Port locat- ed on the back of the unit.
  • Page 7 OPERATING INSTRUCTIONS CONTROL PANEL OPERATION 1) Power ON/OFF - Press the POWER button once to manually turn the unit on. Press the POWER button once more to turn the unit off. 2) Mode Button - Press the MODE button to choose between FAN and DEHUMDIFIER modes. 3) Humidity + and - Buttons - When in Dehumidifier Mode, press the + or - buttons to choose the desired...
  • Page 8 OPERATING INSTRUCTIONS CONTROL PANEL OPERATION Set Timer Auto On- To program the unit to automatically turn on, press the TIME button repeatedly until Timer function is displayed while the unit is off. Press + or - to increase or decrease the timer in 1 hour increments until the desired time increment is displayed.
  • Page 9: Choosing A Location

    CHOOSING A LOCATION A Dehumidifier operating in a basement will have little or no effect in drying out an adjacent enclosed storage area, such as a closet, unless there is adequate circulation of air in and out of the area. Do not use outdoors.
  • Page 10: Maintenance

    Replace Filter - The filter will need to be changed periodically as dirt visible ac- cumulates. This can vary greatly depending on air quality and amount of use. When the filter is dirty, replace it with a Soleus Air Replacement Filter. CAUTION: DO NOT OPERATE THE DEHUMIDIFIER WITHOUT A FILTER.
  • Page 11: Troubleshooting

    TROUBLESHOOTING Problem Possible Causes Solutions Dehumidifier does not start The dehumidifier is unplugged. Make sure the dehumidifier’s plug is pushed completely into the outlet. The fuse is blown / circuit break- Check the house fuse / circuit breaker box and replace fuse or er is tripped.
  • Page 12 TROUBLESHOOTING Problem Possible Causes Solutions Water on the floor Drain Tube is not connected. Install the Drain Tube onto the Drain Port on the back of the unit. See the PRODUCT SETUP Section on Page 6. Drain Tube connection may be Check the Drain Tube connection.
  • Page 13 SELF-DIAGNOSING CODES Self- Diagnosing Description Resolution Code Press Drain button to remove water from internal bucket. If Bucker Full Indicator the error code still appears, please call Customer Services at (877) 665-9765 Temperature Sensor Failure Humidity Sensor Malfunction Please call Soleus Customer Service at (877) 665-9765 Defrost Sensor Malfunction For any questions or Technical Support, please call customer service (877) 665-9765...
  • Page 14: Limited Warranty

    Five Year Compressor Limited Warranty Soleus N.A. warrants the accompanying Soleus Air Dehumidifier to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of TWO (2) years for components and FIVE (5) years for the compressor from the date of original retail purchase in the United States.

Table of Contents