Complete Acknowledgement Principle
The complete acknowledgement principle is always used to control the FM 350-1 from the
user program:
Figure 5-4
The sequence is as follows:
1. If the feedback bit = 0, you can request processing via the user program by setting the
2. The FM 350-1 detects the request, acknowledges it by setting the feedback bit and starts
3. Once the FM 350-1 has set the feedback bit, you can reset the control bit.
4. At the end of processing, the FM 350-1 responds to the resetting of the control bit by
68
Complete Acknowledgement Principle
control bit.
the processing.
resetting the feedback bit.
FM 350-1 Counter module