Philips 300WN5QS/97 Service Manual page 31

Hide thumbs Also See for 300WN5QS/97:
Table of Contents

Advertisement

3. At the submenu, type the letter of your computer's floppy disk drive
followed by :EDID301 (for example, A:\EDID301.exe,)
as shown in Fig. 4.
4. Click
button. The main menu appears (as shown on Fig. 5).
Note:
If the connection is improper, you will see the following error
message before entering the main menu. Meanwhile, the
(read EDID) function will be disable. At this time, please make
sure all cables are connected correctly and fixedly, and the
DDC Instructions
Fig. 4
Command bar
Tools bar
Status bar
Fig. 5
Loading DDC data from monitor
1.
Click
icon on the tools bar to bring up the Configuration
Setup windows as Fig.6
2.
Select the DDC2B as the communication channel.
3.
Enable Factory memory data write function and fill in page address
F0 to the block.
4.
Disable Software DDC function.
5.
Click
button to confirm your selection.
Note: The Factory memory data write function will allow EDID30 to
rewrite serial numbers both Analog DDC IC and main EEPROM
to make sure both S/N are exactly the same. You may confirm the
function by checking the S/N at Product information of the OSD
menu after restarting the monitor.
6.
Click
icon to read DDC EDID data from monitor. The EDID
codes will display on screen as following. (The EDID codes are
depend on the model.) Meanwhile, The status bar will indicate
00% to 100% when reading.
Fig. 7
300WN5
Go to cover page
Fig. 6
31