Exp100 Specifications; Ibm Totalstorage Exp100 Storage Expansion Enclosure Specifications - IBM TotalStorage DS4000 EXP100 Installation, User's, And Maintenance Manual

Storage expansion enclosure
Hide thumbs Also See for TotalStorage DS4000 EXP100:
Table of Contents

Advertisement

EXP100 specifications

Table 6 lists the specifications for the EXP100.
Table 6. IBM TotalStorage EXP100 Storage Expansion Enclosure specifications
Size
v Width: 48.1 cm (18.97 in.)
v Height: 13.2 cm (5.21 in.)
v Depth: 59.7 cm (23.52 in.)
v Drive-ready weight (without disk drive
v Fully configured weight (with 14 disk drives
Electrical input
v Sine-wave input (50 - 60 Hz) is required
v Input voltage low range:
v Input voltage high range:
v Input kilovolt-amperes (kVA),
Environment
v Air temperature
v Humidity
Notes:
1. In general, disk subsystem reliability tends to decrease as the ambient
2. The nonoperating environment must not exceed the operating environment
3. The storage environment must not exceed the operating environment limits for
22
IBM TotalStorage DS4000 EXP100 Storage Expansion Enclosure: Installation, User's and Maintenance Guide
modules installed): 25.9 kg (57 lb)
installed): 40.2 kg (88.4 lb)
– Minimum: 90 V ac
– Maximum: 127 V ac
– Minimum: 198 V ac
– Maximum: 257 V ac
approximately:
– Minimum configuration: 0.06 kVA
– Maximum configuration: 0.39 kVA
– Operating:
- Altitude: 0 - 914 m (3000 ft): 10° -
35° C (50° - 95° F)
- Altitude: 914 m - 2133 m (3000 -
7000 ft): 10° - 32° C (50° - 90° F)
– Storage:
- Altitude: 0 - 914 m (3000 ft): 1° - 60°
C (33° - 140° F)
- Altitude: 914 m (3000 ft):
– 8% - 80%
– noncondensing
temperature of the environment in which it is being used increases. The ambient
temperature in the immediate area of the storage expansion enclosure should
be kept near 22 degrees C (72 degrees F), or lower, to provide better reliability.
limits for longer than 60 days.
longer than 1 year.
Heat dissipation
v Fully configured expansion enclosure (14
1.5 Gbps SATA hard disk drives)
– 1088 BTU per hour
Acoustical noise emission values
For open bay (0 drives installed) and typical
system configurations (eight hard disk drives
installed):
v Sound power (idling):
– 5.9 bel (open bay)
– 6.1 bel (typical)
v Sound power (operating):
– 5.9 bel (open bay)
– 6.2 bel (typical)
v Sound pressure (idling):
– 44 dBA (open bay)
– 46 dBA (typical)
v Sound pressure (operating):
– 44 dBA (open bay)
– 47 dBA (typical)
These levels are measured in controlled
acoustical environments according to ISO
7779 and are reported in accordance with
ISO 9296. The declared sound power levels
indicate an upper limit, below which a large
portion of machines operate. Sound pressure
levels in your location might exceed the
average 1-meter values stated because of
room reflections and other nearby noise.

Advertisement

Table of Contents
loading

Table of Contents