To refill the pot through the rinse hose, use the steps below:
Make certain that the rinse hose is connected to rinse hose connector.
Holding the hose by the handle, place hose nozzle inside the pot.
Hold the lid down over the hose nozzle to prevent shortening splashes.
Position the FILL lever in the THRU HOSE position.
Position the FILTER/OFF/FRY switch to FILTER and shortening will automatically pump into the
pot.
After 1 minute, hold the hose by the handle and carefully raise the lid to check the level of the
shortening.
Let the filter continue to pump the shortening until the fill mark in the fryer pot is reached or until
air starts bubbling through the shortening.
As soon as air is seen in the shortening, position the FILTER/OFF/FRY switch to OFF to prevent
shortening degradation.
Add new shortening if the fill mark has not been reached.

LGF

1. Set the FILTER/OFF/FRY switch to OFF.
2. Remove the fryer basket.
3. Make certain that the FKF filter unit or portable filter unit filter pad is clean and not torn.
4. Position the FKF filter unit or portable filter unit under the main drain valve and make sure it's filter
screen is in place.
5. Ensure that the FKF filter unit or portable filter unit is powered.
6. Move the DRAIN handle slowly to the OPEN position until the shortening starts to flow evenly. This
will prevent excessive splashing of hot shortening.
7. When the pot is empty, place the DRAIN handle in the CLOSED position.
To refill the pot through the drain valve, use the steps below:
Make certain that the braided hose (located on the drain valve) is connected to it's mating part on
the FKF filter unit or portable filter unit.
Close the lid to prevent shortening splashes.
Hot shortening may splash out of the pot causing severe injury when filling the pot if the
lid is not held down over the hose nozzle. To prevent shortening splashes, hold the lid
down over the hose nozzle.
Hot shortening may splash out of the pot causing severe injury when filling the pot if the
lid is not closed. To prevent shortening splashes, close the lid before filling.