Acoustic Localisation Signal; Delay Time Before Warning For No-Movement And Man-Down Alarms; Alarm With Data; Automatic Call After An Alarm - ASCOM 9d24 MkllMessenger User Manual

Table of Contents

Advertisement

User Manual
9d24 Mkll Cordless Telephone
alarm by pressing a key, it is sent and "No-movement/Man-down Alarm" is shown in the
display.
Activate the man-down alarm again
When the man-down alarm has been sent, it is made active again by moving the handset
to upright position or pressing a key.
3.8.6

Acoustic Localisation Signal

A parameter in the handset determines whether or not an Acoustic Localisation Signal
(ALS) should sound after a no-movement and man-down alarm. The ALS is silenced by
pressing the Mute button.
3.8.7

Delay Time before Warning for No-movement and Man-down Alarms

By setting a SIM parameter, the time before the warning for no-movement and man-down
alarms can be delayed for ten minutes, i.e. no-movement and man-down will not be
detected during the time period. When the warning signal sounds, press the Mute button
to delay the time to next warning for ten minutes.
3.8.8

Alarm with Data

Additional data for example a location code, can be sent along with an alarm. The data
must manually be defined and stored by the user. To use the function, one Soft/Hot key in
the handset must be defined as a short-cut to the menu "Edit alarm data", see
a Soft key
is a system dependent function.
3.9

Automatic Call after an Alarm

Note: 9d24 Mkll Protector only.
The handset can be programmed to call a predefined telephone number directly after an
alarm. One Hot key in the handset must be programmed with the specific telephone
number. It can be any external or internal telephone number but also a pre-defined group
of handsets, see
number for all types of alarms or to call different numbers depending on the alarm type.
The specific Hot key must be programmed to dial the phone number, see
key
on page 32.
This is a system dependent function that also require a SIM card parameter setting in the
Cordless Handset.
Note: If a call is connected when the alarm is transmitted, the call will be disconnected
and then the telephone number associated with the Hot key will be called.
3.9.1

Speech Monitoring

The speech monitoring function allows a user in a threatening situation to send an alarm
to a pre-defined group of handsets.
The course of event is that a Hot key in the handset automatically is triggered when an
alarm is activated. The microphone on the handset that sends the alarm is discreetly
activated and will give the answering party opportunity to listen and to take an
appropriate decision on how to act.
2006-03-20/ Ver. PA8
PRELIMINARY
on page 32. The stored data is added to all types of alarm at transmission. This
3.9.1 Speech
Monitoring. The handset can be configured to call the same
TD 92333GB
6.5.8 Edit
6.5.9 Edit a Hot
18

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

9d24 mkll talker9d24 mkll protector

Table of Contents