21.6 Preferences

The dialog Preferences can be opened via the Options menu or directly via F2.
Level Meters
Full scale samples for OVR. Number
of consecutive samples to trigger an
over detection (1 to 10).
Peak Hold Time. Hold time of the peak
value. Adjustable from 0.1 up to 9.9 s.
RMS +3 dB. Shifts the RMS value by
+3 dB, so that full scale level is identical
for Peak and RMS at 0 dBFS.
Mixer Views
FX Send follows highest Submix.
FX Send follows Main Out. Not
supported by the MADIface USB (no
FX).
Center Balance/Pan when changing
Mono/Stereo. When switching a stereo
channel into two mono channels the
pan-pots are set fully left and right. This
option will set them to center instead.
Disable double click fader action.
Prevents unintentional gain settings, for
example when using sensitive touch-
pads.
Dynamic Meters
Not supported by the MADIface USB, as
these settings refer to Compressor and
Expander from other RME devices.
Snapshots
Do not load Main volume/balance.
The values stored in the Snapshot are
not loaded for the Main Out, so the
current setting is not changed.
Device Handling
Always
init
DSP
TotalMix
FX
MADIface USB: always on, as the unit
does not store any. When connecting to
a computer TotalMix FX will immedi-
ately load its settings into the MADIface.
Count MADI Channels per port. In 128 Channel mode the channels shown in TotalMix are
counted 1 to 64 two times.
Disable ASIO Direct Monitoring. Disables ASIO Direct Monitoring (ADM) for the MADI-
face USB within TotalMix FX.
Graphics
Use D2D (Change requires restart). Default on. Can be deactivated to use a compatible
but CPU-taxing graphics mode, in case graphics problems show up.
Brightness correction. Set TotalMix FX screen brightness to your taste, matching the