Repair
Replace Solenoid Inlet Air Regulator (644)
1. Remove Control Box Shrouds.
2. Remove Air Control Assembly (18).
3. Disconnect air line from air regulator (644).
4. Remove gauge (616) from block (643).
5. Remove screws from quick clamps (642) holding air
regulator assembly (644) in place.
6. Open clamps (642) at hinge and pull apart from
block (643).
7. Remove regulator assembly (644) and replace with
new.
617
613
626
619
638
635
618
630
640 631
F
. 5: Air Control Assembly (18)
IG
22
*177
*160
607
641
643
603
642
632
637
636
632
625
628
629
633
627
618
627
8. Follow steps in reverse order to reassemble.
9. Set new air pressure regulator to at least 80-85 psi
(0.55-0.58 MPa, 5.5-5.8 bar).
Replace Purge Box Inlet Air Regulator (160)
1. Remove Control Box Shrouds.
2. Disconnect air line from regulator (160).
3. Remove fittings (177, 161). Remove regulator
assembly (160).
4. Follow steps in reverse order to reassemble.