Air Controls - Graco XM PFP Repair Parts

Plural-component sprayer
Hide thumbs Also See for XM PFP:
Table of Contents

Advertisement

Air Controls

Remove Control Box Shrouds
1. Close main air shutoff valve on air supply line and
on system. Depressurize air line.
2. Remove four nuts (21) and then remove front and
rear shrouds (19, 20).
21
20
19
ti19926a1
Remove Air Control Assembly (18)
1. Remove Control Box Shrouds.
2. Disconnect air motor air lines and system air line.
3. Remove four nuts (17) from front of air controls (18).
See F
. 5, page 22.
IG
4. Pull out assembly (18).
5. Follow steps in reverse order to reinstall air control
assembly.
Replace Flush Pump Air Ball Valve (626)
1. Remove Air Control Assembly (18).
2. Remove two nuts (630) from front of air control
bracket (619). See F
3. Disconnect air line (632) running to ball valve
assembly (626).
4. Replace with new ball valve assembly. See part
number shown in the System Air Controls Module
(255761) section beginning on page 61.
5. Follow steps in reverse order to reassemble.
3A2989V
. 5, page 22.
IG
Replace Flush Pump Air Regulator (625)
1. Remove Air Control Assembly (18).
2. Remove regulator nut (631), and disconnect air
lines (632, 633) running to regulator (625). See F
5 on page 22.
3. Remove regulator assembly and replace with new.
See part number shown in the System Air Con
trols Module (255761) section beginning on
page 61.
4. Follow steps in reverse order to reassemble.
Replace System Air Regulator (645)
1. Remove Air Control Assembly (18).
2. Remove regulator nut and disconnect system air
line. See F
. 5, page 22.
IG
3. Remove screws from quick clamps and open
clamps (642) at hinge.
4. Remove regulator assembly (645) and replace with
new.
5. Follow steps in reverse order to reassemble.
Repair
.
IG
21

Hide quick links: