Rating Plate Information - Napoleon S1 Installation And Operating Instructions Manual

Pedestal models
Table of Contents

Advertisement

Available languages

Available languages

8
2.5

RATING PLATE INFORMATION

For rating plate location, see
EN
"INSTALLATION OVERVIEW" section.
This illustration is for reference only.
Refer to the rating plate on the
appliance for accurate information.
NOTE: The rating plate must
remain with the appliance at all
times. It must not be removed.
W415-1476 / C / 10.03.17
LISTED SOLID FUEL BURNING SPACE HEATER / POÊLE À COMBUSTIBLE SOLIDE
HOMOLOGUÉ TESTED TO: / TESTÉ SELON : UL1482 / ULC S627
9700539 (WSL)
S4
4001657 (NGZ)
4001658 (NAC)
4001659 (WUSA)
POUR INSTALLATION ET
INSTALL AND USE ONLY IN
UTILISATION CONFORM ÉMENT AUX
ACCORDANCE WITH THE
INSTRUCTIONS DU FABRICANT ET
MANUFACTURER'S
AUX CODES LOCAUX DU BÂTIMENT.
INSTRUCTIONS AND LOCAL
HAUTEUR DE PLAFOND MINIMAL
BUILDING CODES.
7PI (2,13m).
MINIMUM CEILING HEIGHT:
PROLONGEMENT
7FT (2.13m)
D'ÂTRE/PROTECTION DU
HEARTH EXTENSION /
PLANCHER COMBUSTIBLE: SI
COMBUSTIBLE FLOOR
INSTALL É SUR UN PLANCHER
PROTECTION: IF INSTALLED
COMBUSTIBLE, L'APPAREIL DOIT
ON A COMBUSTIBLE FLOOR,
ÊTRE PLAC É SUR UNE PLAQUE
APPLIANCE MUST BE PLACED
PROTECTRICE INCOMBUSTIBLE
ON A NON-COMBUSTIBLE
S'ÉTENDANT SUR 18" (455mm) À
FLOOR PROTECTOR
L'AVANT ET 8" (205mm) À L'ARRIÈRE
EXTENDING 18" (455mm) IN
ET SUR LES CÔTÉS.
FRONT AND 8" (205mm) TO
TYPE DE CHIMNÉE: DIAMÈTRE
THE SIDES AND BACK.
MINIMAL DE 6" (152mm)
CHIMNEY TYPE: MINIMUM 6"
APPROUVÉE POUR USAGE
(152mm) DIAMETER
RÉSIDENTIEL. MAISON MOBILE
APPROVED RESIDENTIAL
EMPLOYEZ UNE CHEMINÉE
TYPE FOR MOBILE HOME USE
HOMOLOGUÉE ULC S629 AU
A CHIMNEY LISTED TO ULC
CANADA OU UL 103HT AUX
S629 IN CANADA OR UL 103HT
ÉTATS-UNIS.
IN THE USA.
RACCORD DE CHEMINÉE:
CHIMNEY CONNECTOR: 6"
DIAMÈTRE DE 6" (152mm) D'ACIER
(152mm) DIAMETER MINIMUM
DE CALIBRE 24 MINIMUM. 18"
24 GAUGE STEEL MINIMUM
(455mm) DE DÉGAGEMENT MINIMAL
CLEARANCE FROM
ENTRE LE RACCORD HORIZONTAL
HORIZONTAL CONNECTOR
ET LE PLAFOND.
AND CEILING 18" (455mm).
NE RIEN ENTREPOSER SOUS
DO NOT OBSTRUCT SPACE
L'APPAREIL.
UNDER APPLIANCE.
DES MÉTHODES SPÉCIALES SONT
SPECIAL METHODS ARE
REQUISES LORSQU'UNE CHEMINÉE
REQUIRED WHEN PASSING A
TRAVERSE UN MUR OU UN
CHIMNEY THROUGH A WALL
PLAFOND. VOIR LES INSTRUC-
OR CEILING. SEE INSTRUC-
TIONS ET LES CODES DU
TIONS AND BUILDING CODES.
BÂTIMENT.
DO NOT CONNECT THIS
NE PAS RACCORDER À LA
APPLIANCE TO A CHIMNEY
CHEMINÉE D'UN AUTRE APPAREIL.
FLUE SERVING ANOTHER
COMBUSTIBLE: POUR USAGE AVEC
APPLIANCE.
LE BOIS SEULEMENT. N'UTILISEZ
FUEL: FOR USE WITH WOOD
PAS DE CHENET OU NE
ONLY. DO NOT USE GRATE OR
SURÉLEVEZ PAS LE BOIS.
ELEVATE FIRE. BUILD WOOD
PRÉPAREZ LE FEU DIRECTEMENT
FIRE DIRECTLY ON HEARTH.
SUR L'ÂTRE.
WARNING: RISK OF SMOKE
AVERTISSEMENT: RISQUE
SPILLAGE. OPERATE ONLY
D'ÉCHAPPEMENT DE FUMÉE. TENIR
WITH DOOR FULLY CLOSED.
LA PORTE FERMÉE LORSQUE LE
REPLACE GLASS ONLY WITH
POÊLE FONCTIONNE. REMPLACEZ
CERAMIC GLASS.
LA VITRE PAR UNE VITRE EN
DO NOT OVERFIRE. IF
CÉRAMIQUE SEULEMENT.
APPLIANCE OR CHIMNEY
NE SURCHAUFFEZ PAS L'APPAREIL.
CONNECTORS GLOW, YOU
SI L'APPAREIL OU LES RACCORDS
ARE OVERFIRING. INSPECT
ROUGEOIENT, L'APPAREIL
AND CLEAN CHIMNEY
SURCHAUFEE. INSPECTEZ ET
FREQUENTLY. UNDER
NETTOYEZ LA CHEMINÉE
CERTAIN CONDITIONS OF
FRÉQUEMMENT. DANS CERTAINES
USE CREOSOTE BUILD-UP
CONDITIONS, DES DÉPÔTS DE
MAY OCCUR RAPIDLY.
CRÉOSOTE PEUVENT SE FORMER
OPTIONAL BLOWER KIT:
RAPIDEMENT.
EP-62, 115V, 60HZ, 0.82AMP.
SOUFFLERIE OPTIONNELLE: EP-62,
ROUTE CORD AWAY FROM
115V, 60HZ, 0,82A. TENEZ LE
APPLIANCE.
CORDON ÉLECTRIQUE LOIN DE
DANGER: RISK OF
L'APPAREIL.
ELECTRICAL SHOCK.
DANGER: RISQUE DE SECOUSSE
DISCONNECT POWER
ÉLECTRIQUE. DÉBRANCHEZ AVANT
BEFORE SERVICING
DE PROCÉDER À L'ENTRETIEN.
APPLIANCE.
ENCASTRÉ: INSTALLEZ ET UTILISEZ
INSERT: INSTALL AND USE
SEULEMENT DANS UN FOYER À
ONLY IN SOLID FUEL
COMBUSTIBLE SOLIDE. NE RETIREZ
BURNING FIREPLACES. DO
PAS DE MORTIER, NI BRIQUES DU
NOT REMOVE BRICKS OR
FOYER À COMBUSTIBLE SOLIDE.
MORTAR FROM SOLID FUEL
INSTALLEZ AVEC UNE GAINE
BURNING FIREPLACE.
CONFORME ET UNE PLAQUE DE
INSTALL WITH A POSITIVE
RECOUVREMENT.
FLUE CONNECTOR AND
FACEPLATE.
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
MAXIMUM SIZE:
6" x 11.250"
S4 SERIES RATING PLATE ILLUSTRATED
SILVER ON BLACK BACKGROUND
SPECIFICATIONS:
WATERPROOF, NONWATER SOLUBLE ADHESIVE CAPABLE OF WITHSTANDING A MAXIMUM
TEMPERATURE OF 175°F (79°C).
SERIAL NUMBER TO BE ASCENDING FROM EPA1400 117839
CAUTION MINIMUM LETTER SIZE (18 POINT TYPE) AND 0.12" (8.64 POINT TYPE) FOR THE REMAINDER OF
THAT WARNING WITH VERTICAL SPACING BETWEEN LINES OF 0.046" (3.312 POINT TYPE).
WOLF STEEL LTD
LOG / FIRE WARNING SYMBOL TO BE RED
TITLE: RATING PLATE LABEL EPA1400
CLASS III A-2 PERMANENT LABEL
MATERIAL:
FINISH:
REVISION: B
MM/DD/YY: 11.08.16
CORRECTED ADHESIVE TEMPERATURE LIMIT
MODEL / MODÈLE - EPA 1400
1400
1400L
1402
CONTACT LOCAL BUILDING FIRE OFFICIALS ABOUT RESTRICTIONS AND
INSTALLATION INSPECTION IN YOUR AREA. MODEL 1400 IS SUITABLE FOR USE
IN MOBILE HOMES WHEN USED WITH OUTSIDE AIR INSTALLATION KIT (111KT).
A MINIMUM CLEARANCE OF 18" (457mm) TO THE CHIMNEY CONNECTOR MAY
BE REQUIRED BY THE AUTHORITY HAVING JURISDICTION.
RENSEIGNEZ-VOUS AUPR ÈS DES AUTORITÉS LOCALES DU BÂTIMENT ET DU
SERVICE DES INCENDIES AU SUJET DES RESTRICTIONS ET DES INSPECTIONS
D'INSTALLATION DANS VOTRE RÉGION. LES MODÈLES 1400 PEUVENT ÊTRE
INSTALLÉS DANS UNE MAISON MOBILE SI INSTALLÉS CONJOINTEMENT AVEC UNE
PRISE D'AIR EXTÉRIEUR (111KT). UN DÉGAGEMENT MINIMAL DE 18" (457mm)
JUSQU'AU RACCORD DE LA CHEMINÉE PEUT ÊTRE EXIGÉ PAR L'AUTORITÉ AYANT
JURIDICTION.
BACK WALL (M/A)
BACK WALL (M/A)
B
45°
A
IF THE STOVE IS TO BE INSTALLED ON A COMBUSTIBLE FLOOR, IT MUST BE
PLACED ON AN APPROVED NON-COMBUSTIBLE HEARTH PAD, THAT
EXTENDS 8" (200mm) BEYOND THE STOVE SIDES AND BACK, AND 18"
(455mm) TO THE FRONT.
SI LE PO Ê LE EST INSTALL É SUR UN PLANCHER COMBUSTIBLE, IL DOIT ÊTRE PLACÉ
SUR UNE BASE DE PROTECTION INCOMBUSTIBLE CERTIFÉE QUI DOIT DÉPASSER
LES CÔTÉS ET L'AMÉRE DU PO Ê LE DE 8" (200mm) ET SE PROLONGER DE 18"
(455mm) SUR LE DEVANT.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL WITH SINGLE WALL
CHIMNEY CONNECTOR / D ÉGAGEMENTS MINIMAUX AUX MATÉRIAUX
COMBUSTIBLES AVEC RACCORD DE CHEMINÉE À PAROI SIMPLE:
FROM HEATER / DU POÊLE
RESIDENTIAL / RÉSIDENTIEL
1400
A
12IN/PO (305 mm)
B
12IN/PO (305 mm)
C
6IN/PO (152 mm)
USING DOUBLE WALL CONNECTOR /
UTILISATION D'UN CONDUIT DE
RACCORDEMENT À DOUBLE PAROI
1400
S4
A
10IN/PO (254 mm)
A
16IN/PO (406 mm)
B
6IN/PO (152 mm)
B
6IN/PO (152 mm)
C
C
4IN/PO (102 mm)
4IN/PO (102 mm)
*
ONLY MODELS 1400 AND S4 MAYBE INSTALLED INTO A MOBILE HOME OR
COMBUSTIBLE ALCOVE USING LISTED DOUBLE WALL CONNECTOR. MODELS
1400 AND S4 MAY BE INSTALLED INTO A MOBILE HOME IN THE UNITED
STATES ONLY.
*
LE MODÈLES 1400 ET S4 NE PEUT ÊTRE INSTALLÉ QUE DANS UNE MAISON
MOBILE AUX ÉTATS-UNIS SEULEMENT.
THIS WOOD APPLIANCE NEEDS PERIODIC INSPECTION AND REPAIR FOR
PROPER OPERATION. CONSULT THE OWNER'S MANUAL FOR FURTHER
INFORMATION. IT IS AGAINST UNITED STATES FEDERAL REGULATIONS TO
OPERATE THIS WOOD APPLIANCE IN A MANNER INCONSISTENT WITH THE
OPERATING INSTRUCTIONS IN THE OWNER'S MANUAL.
CET APPAREIL AU BOIS DOIT FAIRE L'OBJECT D'UNE INSPECTION ET D'UN
ENTRETIEN PÉRIODIQUES POUR UN FONCTIONNEMENT ADÉQUAT. CONSULTEZ
LE MANUEL D'INSTRUCTIONS POUR PLUS D'INFORMATION. LES RÈGLEMENTS
FÉDÉRAUX DE L'ÉTATS-UNIS INTERDISENT D'UTILISER CET APPAREIL DE
CHAUFFAGE D'UNE MANIÈRE ALLANT À L'ENCONTRE DES INSTRUCTIONS DE
FONCTIONNEMENT CONTENUES DANS CE MANUEL.
LISTED SOLID FUEL BURNING FIREPLACE INSERT /
ENCASTRÉ À COMBUSTIBLE SOLIDE HOMOLOGUÉ
TESTED TO / TESTÉ SELON :
ULC S628 / UL 1482
CLEARANCES TO COMBUSTIBLE CONSTRUCTION /
D ÉGAGEMENTS AUX MATÉRIAUX COMBUSTIBLES:
(MEASURED TO UNIT / À PARTIR DE L'APPAREIL)
CEILING / PLAFOND
A SIDE FACING / CÔTÉ
D
C
B TOP FACING / DESSUS
B
C MANTEL / TABLETTE
A
D SIDE WALL / MUR LATÉRAL
FLOOR / PLANCHER
*
CLEARANCE TO EDGE OF FLASHING / DÉGAGEMENT AU
BORD DE LA FAÇADE
EPA1400
MODEL: S4, 1400, 1400L, 1402, 1450, 1400C
SHEET 1 0F 1
1400C
1450
8"
B"
8"
8"
A"
C
18"
ALCOVE
S4
A
12IN/PO (305 mm)
B
16IN/PO (406 mm)
6IN/PO (152 mm)
C
*
MAISON / MOBILE HOME
1400
S4
A
10IN/PO (254 mm)
A
16IN/PO (406 mm)
B
6IN/PO (152 mm)
B
6IN/PO (152 mm)
C
C
4IN/PO (102 mm)
4IN/PO (102mm)
EPI 1402
*
1 IN/PO (25mm)
28 IN/PO (710mm)
28 IN/PO (710mm)
17 IN/PO (430mm)
W385-2031 / B
DRAWING: W385-2031
DRAWN BY: J.K.
MM/DD/YY: 03.18.16
CHECKED BY: 11.08.16_C.L.
A
B

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S4S9