6. Focus Test
Procedure
Inspection item
Criteria
7.Unbalance test
Procedure
Inspection item
Criteria
Note:If focus could not clarify,you can use the unbanlance test that you put
a white paper far away screen front or behind until the focus is best ,then
measure the distance from paper and screen within the specification.
8. Color Performance
Procedure
Inspection item
- Test equipment: video generator.
- Test signal: analog 800x600@60Hz
- Test Pattern: full screen
- Focus check
- look at the entire screen, focus shall be clear, crisp,
and sharp over the entire surface of the display
pattern. (Blur word on one of the corner after
adjustment is acceptable. However, the word should
at least be recognizable.)
- Test equipment: video generator.
- Test signal: analog 800x600@60Hz
- Test Pattern: full screen
- Unbalance check
- Test signal:analog 800x600@60Hz
- Unbalance <=37cm@60"
- Test equipment: video generator.
- Test signal: 800x600@60Hz, 1080i
800x600@60Hz, 1080i
- Test Pattern: 64 gray RGBW
Please get into service mode.Use
720p & 1080p signal, pattern to do color
performance. Color cannot discolor to purple and
blue.
- Check if each color level is well-functioned.
- Color saturation
800x600@60Hz
@60Hz
@60Hz, 1080i
S310e/X312
Full screen