6 NC Machine Data (NC MD), NC Setting Data (NC SD)
6.5 Spindle-specific MD (spindle data)
452*
Default value
0
If M19 is started by the PLC via the "Position spindle" and "PLC spindle control" signals, the
NC positions the spindle to the angle specified in NC MD 452*.
453*
Default value
1
NC MD 453* defines the mode group to which the spindle is to belong.
Mode groups without spindles are permitted.
Note:
Spindles generally only react to the mode group RESET assigned to this MD. The spindle
does not stop when a program is aborted with channel reset.
455*
Default value
32
456*
Default value
5 625
The internal calculations for the spindle are made in the resolution provided by the measuring
system (measuring system resolution). In order to be able to carry out the internal conversions
to the measuring system resolution, the latter must be entered in MD 456*. As for axes, input
is not made via the encoder graduation and pulse multiplication but via variable increment
weighting. This makes it possible to use spindle encoders with an arbitrary number of pulses
and measuring gear.
Note: as from SW 4
MD 2420* 2421* and 2422* in the MDD are used to automatically calculate MD 455* and 456*.
_______
1)
Spindles can be allocated to another mode group via the warm restart function without having to execute a
hardware reset (for a detailed description of the warm restart function, see Section entitled "Functional
Descriptions").
2)
MD 455* and 456* are invalid and are not evaluated, if the same measuring system is used for the spindle
and C axis. MD 364* and 368* are valid instead.
6–72
More user manuals on
Spindle position for external M19
Lower input limit
+0
Lower input limit
+1
u: Pulses variable increment weighting
Lower input limit
0
v: Traversing path variable increment weighting
Lower input limit
0
ManualsBase.com
Upper input limit
35 999
Mode group
Upper input limit
+1, 2
6 (as from SW 4)
2)
Upper input limit
65 000
9999 9999 (as from SW 2)
Upper input limit
65 000
9999 9999 (as from SW 2)
©
Siemens AG 1992 All Rights Reserved
10.94
Active on
NC Stop
Units
0.01°
Active on
Power On
1)
Units
Active on
Power On
Units
Active on
2)
Power On
Units
6FC5197- AA50
SINUMERIK 840C (IA)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-d

Table of Contents