Configuration / project engineering
5.6 Configuration with Web Based Management
Receive Errors
● ACL discarded frames
● Fragmentation errors
● Encryption errors
● Duplicate frames
● FCS errors
● Header CRC error
● Decrypt CRC error
162
Displays all client registration attempts that were blocked by the Access Control List.
Sum of all failed fragmentations. One of the fragments was not received or received too
late.
Is incremented if a frame is received in which the WEP bit is set and the device operates
without encryption, or the reverse situation when a packet is received without a WEP bit
and encryption is enabled.
Sum of all frames received twice.
Sum of all packets received in which the checksum was incorrect.
Sum of all packets received in which the header checksum was incorrect.
Sum of all packets received in which the checksum of the encrypted data buffer was
incorrect.
Operating Instructions, Release 08/2007, C79000-G8976-C221-02