Clearing Password Check And Bios Recovery; Clearing Password Check; Steps For Clearing Bios Password Check; Clear Cmos Jumper - Acer G630 Service Manual

Hide thumbs Also See for G630:
Table of Contents

Advertisement

Clearing Password Check and BIOS Recovery

This section provides you with the standard operating procedures of clearing password and BIOS recovery for
eMachines G630/G430. The machine provides one Hardware Open Gap on main board for clearing password
check, and one Hotkey for enabling BIOS Recovery.

Clearing Password Check

Steps for Clearing BIOS Password Check

If users set BIOS Password (Supervisor Password and/or User Password) for a security reason, BIOS will ask
the password during systems POST or when systems enter to BIOS Setup menu. However, once it is
necessary to bypass the password check, users need to short the HW Gap to clear the password by the
following steps:
1.
Power Off the system, and remove HDD, AC and Battery from the machine.
2.
Disconnect the RTC Battery cable and locate the R379 jumper.
3.
Use an electric conductivity tool to short the two points of the HW Gap.
4.
Plug in AC, keep the short condition on the HW Gap, and press Power Button to power on the system till
BIOS POST finish. Then remove the tool from the HW Gap.
5.
Restart system. Press F2 key to enter BIOS Setup menu.
6.
If there is no Password request, BIOS Password is cleared. Otherwise, please follow the steps and try
again.
NOTE: These steps are only for clearing BIOS Password (Supervisor Password and User Password).

Clear CMOS Jumper

Item
R379
Chapter 5
Downloaded from
www.Manualslib.com
R379
Description
Clear CMOS Jumper
manuals search engine
Location
Thermal Module Bay, under Modem Board
141

Advertisement

Table of Contents
loading

This manual is also suitable for:

G430