Table 8-3: Calculated Exposure Distances And Power Compliance Margins - Motorola PMP 320 Hardware Installation

Table of Contents

Advertisement

Table 8-3
resulting power compliance margins for each frequency band and antenna combination.
Details of Exposure Separation Distances Calculations and Power Compliance Margins
Regulatory, Legal, and Safety Notices
Table 8-3
Calculated exposure distances and power compliance margins
P( dBm )
3630APC
3630SM
These are conservative distances:
They are along the beam direction (the direction of greatest energy). Exposure to the sides
and back of the module is significantly less.
In the case of collocated APs, they assume all APs are oriented in the same direction,
which is a worst-case calculation.
They meet or exceed sustained exposure limits for the general population (not just
short-term occupational exposure limits).
The calculated compliance distance d is overestimated because the far-field equation
models the antenna(s) as a point source and neglects the physical dimension of the
antenna(s).
Table 8-4
Radio Module with integrated antenna
Module with Reflector Dish
Module with LENS
Antenna of connectorized 5.7 GHz AP
Antenna of connectorized
or integrated 900 MHz
module
Indoor 900 MHz SM
8-38
shows calculated minimum separation distances d, recommended distances and
P( W )
25.1
0.324
27.06
0.508
Exposure separation distances
Module Type
Preliminary
G
S
16.5
14.5
Separation Distance from Persons
At least 20 cm (approximately 8
inches)
At least 1.5 m (approximately 60
inches or 5 feet)
At least 0.5 m (approximately 20
inches)
At least 30 cm (approximately 12
inches)
At least 60 cm (approximately 24
inches)
At least 10 cm (approximately 4
Distance (cm ,
Calculated )
10
10
PMP320HDW2v1
Chapter 8:
33.92
33.76
JUL 2010

Advertisement