Sony CFD-G500 Service Manual page 13

Hide thumbs Also See for CFD-G500:
Table of Contents

Advertisement

TUNER SECTION
0 dB = 1 µV
• AM Section
Setting:
RADIO BAND•AUTO PRESET button: AM, MW or LW
AM RF signal
generator
30% amplitude
modulation by
400 Hz signal
• FM Section
Setting:
RADIO BAND•AUTO PRESET button: FM
FM RF signal
generator
75 kHz frequency
deviation by 1 kHz signal
output level : as low as possible
• Connecting Level Meter (FM, AM or MW and LW)
set
i jack (J321)
• Connecting Digital Voltmeter (FM, AM or MW and LW)
• Repeat the procedures in each adjustment several times, and
the frequency coverage and tracking adjustments should be
finally done by the trimmer capacitors.
100 k Ω
TP (VT)
Put the lead-wire
antenna close to
the set.
TP (FM IN)
0.01 µ F
set
level meter
(range: 0.5–5 V ac)
32 Ω
digital
voltmeter
AEP, UK, East European, Russian Models
MW IF ADJUSTMENT
Adjust for a maximum reading on level meter.
450 kHz
MW FREQUENCY COVERAGE CHECK
Frequency Display
Reading on Digital voltmeter
Adjustment Part
MW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3-1
621 kHz
LW FREQUENCY COVERAGE ADJUSTMENT
Frequency Display
Reading on Digital voltmeter
Adjustment Part
LW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3-2
162 kHz
US, Canadian, E, Singapore, Australian Models
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
450 kHz
AM FREQUENCY COVERAGE ADJUSTMENT
Frequency Display
Reading on Digital voltmeter
Adjustment Part
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
620 kHz
FM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
10.7 MHz
FM FREQUENCY COVERAGE ADJUSTMENT
Frequency Display
Reading on Digital voltmeter
Adjustment Part
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
87.5 MHz
Adjustment Location: See page 14.
CFD-G500/G500L
T1
531 kHz
1,611 kHz
1.0 ± 0.5 V
5.2 ± 0.6 V
<confirmation>
<confirmation>
CT3
1,404 kHz
153 kHz
279 kHz
0.6 ± 0.3 V
5.0 ± 0.1 V
<confirmation>
L4
CT5
261 kHz
T1
530 kHz
1,710 kHz
1.0 ± 0.05 V
5.3 ± 0.7 V
L4
<confirmation>
CT3
1,400 kHz
T2
87.5 MHz
108 MHz
1.3 ± 0.3 V
3.0 ± 0.2 V
<confirmation>
L2
CT1
108 MHz
13