7.4 CF (Compact Flash)

CF Removal
(1) Turn OFF the Controller and unplug the power connector.
(2) Remove the Top Panel. (Mounting screws ×10)
(3) Remove the CF mounting screw (×1).
(4) Pull the CF toward the direction of the arrow in
CF Installation
(1) Insert a new CF toward the opposite direction of the arrow in the picture above.
(2) Tighten the CF mounting screw (×1).
(3) Mount the Top Panel. (Mounting screws ×10)
(4) Plug in the power connector. Turn ON the Controller and make sure that the
RC90 (EPSON RC+ 7.0) Rev.8
Maintenance 7. Maintenance Parts Replacement Procedures
the picture.
Controller starts properly without any vibration or abnormal noise.