Discussion Device - Bosch CCS 1000 D Operation Manual

Digital discussion system
Hide thumbs Also See for CCS 1000 D:
Table of Contents

Advertisement

Digital Discussion System
7.2

Discussion Device

Figure 7.2: Exchanging the buttons on the Discussion Device
The Discussion Device is delivered as a participant's Discussion Device. To configure the
Discussion Device as a 'chairperson's Discussion Device':
1.
2.
3.
4.
5.
Bosch Security Systems B.V.
6 2
Unplug the Discussion Device from the system cabling.
Use the exchange tool (1) to push the single microphone button (2) from the Discussion
Device as shown (put the single button in a safe place).
Preposition and then gently press the chairperson's priority button (3) and microphone
button (4) into place. Do not use excessive force!
Set the slide‑switch (2) at the base of the Discussion Device from the 'participant's
setting (0)' to the 'chairperson's setting (1)'. See following figure.
Reconnect the Discussion Device to the system cabling. A restart of the system is not
necessary.
6 1
6 2
6 3
Operation manual
Configuration | en
6 4
27