2.3
BULKHEADS
NOTE: Bulkhead covers need to be removed.
Connect the main burner gas flex line
A.
and the pilot line to the gas fittings on the
bulkheads located under the valve access
opening.Care must be taken to ensure the
pilot line isn't damaged and ensuring gas
tight connections are made.
Connect the pilot electrode lead to the
B.
bulkhead matching the 3/16" flag with the
3/16" bulkhead spade. Do the same with the
1/4" spark lead to the 1/4" bulkhead spade.
Ensure the venturi tubes are over the orifice
C.
before lighting.
Check for gas leaks by brushing on a soap
D.
and water solution. Do not use open flame.
After leak test has been performed re-install
E.
access panel with gasket.
Main
Burner Gas
Connection
Pilot Tube
Gas Connection
Bulkhead
Pilot
Electrode
Lead
W415-1632 / C / 10.21.16
3
EN