2.3

BULKHEADS

NOTE: Bulkhead covers need to be removed.
A.
Connect the main burner gas fl ex line
and the pilot line to the gas fi ttings on the
bulkheads located under the valve access
opening.Care must be taken to ensure the
pilot line isn't damaged and ensuring gas
tight connections are made.
B.
Connect the pilot electrode lead to the
bulkhead matching the 3/16" fl ag with the
3/16" bulkhead spade. Do the same with the
1/4" spark lead to the 1/4" bulkhead spade.
C.
Ensure the venturi tubes are over the orifi ce
before lighting.
D.
Check for gas leaks by brushing on a soap
and water solution. Do not use open fl ame.
E.
After leak test has been performed re-install
access panel with gasket.
Main
Burner Gas
Connection
Pilot Tube
Gas Connection
Bulkhead