4.3.1

Digital inputs/outputs (DIs/DOs)

SINAMICS V90 supports free assignment of signals to the following digital input and output
terminals depending on the control mode selected:
DI1 to DI8 -- Assignable with parameters p29301 to p29308
DO1 to DO6 -- Assignable with parameters p29330 to p29335
Exception: DI9 and DI10
DI9 is permanently assigned with the signal EMGS (emergency stop) and DI10 is
permanently assigned with the signal C-MODE (change mode).
For detailed information about default DI/DO signal assignments, see the table below:
Pin No.
Digital in-
puts/outputs
5
DI1
6
DI2
7
DI3
8
DI4
9
DI5
10
DI6
11
DI7
12
DI8
30
DO1
31
DO2
32
DO3
33
DO4
34
DO5
35
DO6
Note
The selected DI signal will respond with a delay time of 8 to 16 ms.
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 07/2015, 6SL3298-0AV60-0BP0
Parameters
Index 0 (PTI)
p29301
1 (SON)
p29302
2 (RESET)
p29303
3 (CWL)
p29304
4 (CCWL)
p29305
5 (G-CHANGE)
p29306
6 (P-TRG)
p29307
7 (CLR)
p29308
10 (TLIM1)
p29330
p29331
p29332
p29333
p29334
p29335
4.3 Control/Status interface - X8
Default signals/values
Index 1 (IPos)
Index 2 (S)
1 (SON)
1 (SON)
2 (RESET)
2 (RESET)
3 (CWL)
3 (CWL)
4 (CCWL)
4 (CCWL)
5 (G-CHANGE)
12 (CWE)
6 (P-TRG)
13 (CCWE)
21 (POS1)
15 (SPD1)
22 (POS2)
16 (SPD2)
1 (RDY)
2 (FAULT)
3 (INP)
5 (SPDR)
6 (TLR)
8 (MBR)
Connecting
Index 3 (T)
1 (SON)
2 (RESET)
3 (CWL)
4 (CCWL)
12 (CWE)
13 (CCWE)
18 (TSET)
19 (SLIM1)
69