4
BMC (Hexapole) Magnet.
If the red, green and blue dots are not balanced or aligned,
then use the BMC magnet to adjust in the manner described
below.
R G
B
R
G
R
B
R
G
G
(2) Dynamic Convergence Adjustment
Preparation:
Before starting this adjustment, adjust the horizontal static
convergence and the vertical static convergence
B
R
B
R
G B
B
G
R
B
TLV
– 23 –
YCH Rotate YCH VOL on DY
TLV
Insert
TLH
Correction Plate to DY Pocket (Left or
Right)
ON DY:
YCH
(3) Screen-corner Convergence
b
a-d : screen-corner
misconvergence