High Limit Thermostat (Electric) - GE GFDR485GF Technical Service Manual

Louisville built front load dryers
Hide thumbs Also See for GFDR485GF:
Table of Contents

Advertisement

High Limit Thermostat (Electric)

See Electric High Limit Thermostat Location on
page 41.
Operating Voltage: 240 VAC
Opens at 308° + - 8°F
Closes at 248° + - 12°F
Label Color: Purple
High Limit Thermostat Removal
1. Disconnect power from the unit.
2. Remove the drum.
See Drum Removal on page 35.
3. Remove the high limit thermostat wires.
4. Remove the two 1/4 in. hex screws that hold the
high limit thermostat to the heater housing.
Inlet Thermostat (Electric)
See Electric Inlet Thermostat Location on page 41.
Operating Voltage: 240 VAC
Opens at 190° + - 5°F
Closes at 175° + - 5°F
Label Color: Red
Electric Inlet Thermostat Removal
1. Disconnect power from the unit.
2. Remove the drum.
See Drum Removal on page 35.
3. Remove the inlet thermostat wires.
4. Remove the two 1/4 in. hex screws that hold the
inlet thermostat to the heater housing.
Outlet Thermostat (Electric)
See Outlet Thermostat Location on page 17.
Operating Voltage: 240 VAC
Closes at 155° + - 5°F
Opens at 165° + - 5°F
Label Color: Blue
Electric Outlet Thermostat Removal
1. Disconnect power from the unit.
2. Remove the drum.
See Drum Removal on page 35.
3. Remove the outlet thermostat wires.
4. Remove the two 1/4 in. hex screws that hold the
outlet thermostat to the blower housing.