FX Series Programmable Controlers
X001
M5
Return to
Operation
zero point
being stopped
X002
M5
Operation
JOG(+)
being stopped
*2
X003
M5
Operation
JOG(-)
being stopped
*2
X004
M5
Positioning
Operation
in normal
being
rotation
stopped
X005
M5
Positioning
Operation
in reverse
being
rotation
stopped
*2 The maximum size of a JOG command is 999,999 pulses, as this is the maximum number
of output pulses for a FNC 158 (DRVI) instruction. If a greater distance is required execute
more than one JOG command.
M10
Zero point
return
completion flag
M10
Zero point
return
completion flag
Resets the zero point return
RST
M10
completion flag.
Resets the normal rotation
RST
M12
positioning completion flag.
Resets the reverse rotation
RST
M13
positioning completion flag.
Drives the zero point return state
SET
S0
(S0).
Resets the normal rotation
RST
M12
positioning completion flag.
Resets the reverse rotation
RST
M13
positioning completion flag.
Drives the jog (+) state (S10).
SET
S10
Resets the normal rotation
RST
M12
positioning completion flag.
Resets the reverse rotation
RST
M13
positioning completion flag.
Drives the jog (-) state (S11).
SET
S11
Resets the normal rotation
RST
M12
positioning completion flag.
Resets the reverse rotation
RST
M13
positioning completion flag.
Drives the normal rotation
SET
S12
positioning state (S12).
Resets the normal rotation
RST
M12
positioning completion flag.
Resets the reverse rotation
RST
M13
positioning completion flag.
Drives the reverse rotation
SET
S13
positioning state (S13).
Applied Instructions 5
5-161