Read completely, then follow step by step.
Select the best location
1. Indoor unit
• Do not have any heat or steam near the
unit.
• Select a place where there are no
obstacles in front of the unit.
• Make sure that condensation drainage can
be conveniently routed away.
• Do not install near a doorway.
• Ensure that the space around the teft and
right of the unit is more than 5cm(2"). The
unit should be installed as high on the wail
as possible, allowing a minimum of
5cm(2") from ceiling.
• Use a stud finder to locate studs to prevent
unnecessary damage to the wail.
More than
'More than 5cm(2")
5cm,
• Rooftop/nsta//ations:
If the outdoor unit is installed on a roof
structure, be sure to level the unit. Ensure the
roof structure and anchoring method are
adequate for the unit location. Consult local
codes regarding rooftop mounting.
Piping length and elevation
Pipe Size
Max
Max
Additional
Bevation
length
Refrigerant
GAS LIQUID
_D
@
(g/m)
3/8"
1/4"
8m(26ft)
15m(50ft)
20
1/2"
1/4"
8m(26ft)
15m(50ft)
20
More than 2.3m(7.5ft)'
More than
5em(2")
_io
_ ,/_ CAUTION:
ndoorunit onthewallwheretheheight
orsmorethan2.3meters(7.5ft),
|
2. Outdoor unit
• If an awning is built over the unit to prevent
direct sunlight or rain exposure, make sure
that heat radiation from the condenser is
not restricted.
• Ensure that the space around the back
and sides is more than 10cm. The front of
the unit should have more than 70cm of
space.
• Do not place animals and plants in the
path of the warm air.
• Take the air conditioner weight into
account and select a place where noise
and vibration are minimum.
• Select a place so that the warm air and
noise from the air conditioner do not
disturb neighbors.
more than
more than
10cm(4") _
10cm(4")
more than
70cm(28")
Outdoor unit
Ind ® _
ur___
Outdoor
unit
In case more than 5m(16,4ft)
__
CAUTION
J_
1
, Capacity is basedonstandard lengthandmaximum
/
. allowance lengthis onthebasis ofreliability,
/
• Oi!trapshould beinstalled every 5~7meters(16,4~23ft),