Download Print this page

Battery Replacement - Honeywell SiXCT Installation Instructions

Six series

Advertisement

Enroll and Set Up
NOTE: The SiXCT can be enrolled and programmed
before or after installation.
1. Set the Lyric Controller in Programming Mode and
go to Zone Programming. Select Add New, then
Serial Number. Follow the controller's instructions
to begin enrollment.
2. Pull the battery tab to activate the SiXCT and begin
the enrollment process.
3. The LED flashes (up to about 20 seconds*) during
enrollment.
• The device sends its unique MAC ID (Serial
Number) and Services information to the
controller.
• The controller registers the device and displays
the transmitter data on screen.
*NOTE: Enrollment time varies depending on the
signal strength between the device and the controller.
4. When done, the LED is ON for 3 seconds and the
control beeps to confirm enrollment.
5. Trigger the device again to complete enrollment
and select SAVE.
If the device is not successfully enrolled during the
enrollment period, the LED turns off and the device
powers down. Activate a tamper, wired service (loop)
or the reed switch to restart the enrollment process.
The device can also be manually enrolled. See the
Controller's Programming Guide for details.
Follow instructions in the Controller's programming
guide to program the SiXCT services (the default
service is "Reed"):
• Reed switch / Magnet
• External device connected / Terminal block
(unsupervised)
After enrolling, update the SiXCT firmware (via the
Controller) to ensure the latest version is used. See
the Controller's instructions.

Battery Replacement

• Push the bottom latch of the mounting
bracket back to disengage it. Then slide the
back housing, up and out to remove it from
the mounting bracket.
• Slide the front and back housings in opposite
directions and pull the housings apart.
• Remove the battery, wait 10 seconds, then
insert a new battery. Recommended
batteries:
Panasonic CR123A
Duracell DL123
• Place the front and back housings together
and slide them together as shown.
BATTERY CAUTION: Risk of fire, explosion and burns.
Do not recharge, disassemble, heat above 212° F (100° C)
or incinerate. Dispose of used batteries properly. Keep
away from children.
Honeywell 466
Duracell DL123A
NOTE: Once enrolled in a system, the SiXCT cannot be used
with another controller until it is removed from the current
controller. See the Controller's instructions for details.

Advertisement