Install The Rack Rails; Power Supply/Cooling Fan Modules - Dell SC7020 Owner's Manual

Hide thumbs Also See for SC7020:
Table of Contents

Advertisement

Install the Rack Rails

Perform the following steps to install rack rails for an SC7020 storage systems.
Steps
1.
Install the replacement rack rails in the rack.
2.
Install the storage system in the rack.
3.
Tighten the screws in the chassis ears that secure the chassis to the rack.
Figure 9. Tighten the Screws
4.
Reconnect the cables to the storage system.
5.
Start up the storage system.
Next steps
Use SupportAssist to send diagnostic data to Dell Technical Support.

Power Supply/Cooling Fan Modules

The SC7020 storage system supports two hot-swappable power supply/cooling fan modules.
The cooling fans that cool the storage system and the power supplies are integrated into the power
supply/cooling fan module and cannot be replaced separately. If one power supply/cooling fan module
fails, the second module continues to provide power to the storage system.
NOTE: When a power supply/cooling fan module fails, the cooling fan speed in the remaining
module increases significantly to provide adequate cooling. The cooling fan speed decreases
gradually when a new power supply/cooling fan module is installed.
16
Replacing SC7020 Storage System Components

Advertisement

Table of Contents
loading

Table of Contents