d.
Remove the webcam/microphone module (3).
The webcam/microphone module is available using spare part number 833962-005. The webcam/
microphone module spare part kit includes 2 microphone rubber isolators and double-sided
adhesive but does not include the webcam/microphone module cable. The webcam/microphone
module cable is available using spare part number 856010-001.
6.
If it is necessary to replace the G-sensor board:
a.
Remove the display panel assembly.
b.
Release the shielding (1) that covers the G-sensor board.
c.
Release the ZIF connector (2) to which the display panel cable is attached, then disconnect
the display panel cable from the G-sensor board.