Preface
Introduction
Installing the Device
Communication Ports
Technical Specifications
Dimension Drawings
Certification
1
2
3
4
5
6

Advertisement

Table of Contents
loading

Summary of Contents for Siemens RUGGEDCOM i803

  • Page 1 Preface Introduction Installing the Device RUGGEDCOM i803 Communication Ports Technical Specifications Dimension Drawings Installation Guide Certification 6/2014 RC1005-EN-02...
  • Page 2: Security Information

    Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 3: Table Of Contents

    RUGGEDCOM i803 Installation Guide Table of Contents Table of Contents Preface ........................ Alerts ..............................v Related Documents ..........................v Accessing Documentation ........................v Training .............................. vi Customer Support ..........................vi Chapter 1 Introduction ......................1.1 Feature Highlights ........................1 1.2 Ports, Controls and Indicator LEDs ....................2 1.3 Memory Slot ..........................
  • Page 4 RUGGEDCOM i803 Table of Contents Installation Guide Chapter 5 Dimension Drawings ..................Chapter 6 Certification ......................6.1 Agency Approvals ........................19 6.2 FCC Compliance ........................19 6.3 Industry Canada Compliance ...................... 20 6.4 EMI and Environmental Type Tests ..................... 20...
  • Page 5: Preface

    Installation Guide Preface Preface This guide describes the RUGGEDCOM i803 (i-Series) product line. It describes the major features, installation, commissioning and important technical specifications. It is intended for use by network technical support personnel who are responsible for the installation, commissioning and maintenance of the device.
  • Page 6: Training

    Siemens sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, please contact Siemens Customer Support through any of the following methods: • Online Visit http://www.siemens.com/automation/support-request...
  • Page 7: Introduction

    RUGGEDCOM i803 Chapter 1 Installation Guide Introduction Introduction The RUGGEDCOM is a compact, fully managed Ethernet switch designed to operate reliably in harsh industrial environments. The flexibility of the allows the user to choose from managed or unmanaged, regular or extended temperature, fiber optical or copper interfaces, and fast or Gigabit Ethernet.
  • Page 8: Ports, Controls And Indicator Leds

    Chapter 1 RUGGEDCOM i803 Introduction Installation Guide Rated for Reliability in Harsh Environments • Immunity to EMI and heavy electrical surges • Exceeds IEC 61000-6-2 (generic industrial) • Hazardous Location Certification: Class 1 Division 2 • -20 to +60 °C (-4 to 140 °F) operating temperature (optional -40 to +85°C or -40 to 185 °F) •...
  • Page 9: Memory Slot

    RUGGEDCOM i803 Chapter 1 Installation Guide Introduction MicroSD Port This port houses the microSD card that may optionally contain the firmware and configuration for the device. For more information, refer to Section 1.3, “Memory Slot”. RS232 Serial Console Port This port is for interfacing directly with the device and accessing initial management functions.
  • Page 10 RUGGEDCOM i803 Chapter 1 Installation Guide Introduction Memory Slot...
  • Page 11: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd. could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 12: Connecting Power

    Chapter 2 RUGGEDCOM i803 Installing the Device Installation Guide Figure 2: DIN Rail Mounting 1. DIN Rail 2. DIN Rail Bracket Pull the release on the bracket down and slide the device onto the DIN rail. Let go of the release to lock the device in position.
  • Page 13 RUGGEDCOM i803 Chapter 2 Installation Guide Installing the Device Figure 3: Terminal Block Wiring – Single DC Power Supply Input 1. Positive Terminal 2. Negative Terminal 3. GND Terminal 4. Chassis Ground Terminal Figure 4: Terminal Block Wiring – Dual DC Power Supply Inputs 1.
  • Page 14: Connecting The Failsafe Alarm Relay (If Equipped)

    Chapter 2 RUGGEDCOM i803 Installing the Device Installation Guide Section 2.3 Connecting the Failsafe Alarm Relay (If Equipped) The failsafe relay can be configured to latch based on alarm conditions. The NO (Normally Open) contact is closed when the unit is powered and there are no active alarms. If the device is not powered or if an active alarm is configured, the relay opens the NO contact and closes the NC (Normally Closed) contact.
  • Page 15: Communication Ports

    RUGGEDCOM i803 Chapter 2 Installation Guide Installing the Device Name Description Comment RJ45 Male Female Data Set Ready Carrier Detect Reserved (Do Figure 6: RJ45 Console Port Pin Configuration Not Connect) Data Terminal Ready Signal Ground Receive Data (to DTE)
  • Page 16 RUGGEDCOM i803 Chapter 2 Installation Guide Installing the Device Connecting to the Device...
  • Page 17: Communication Ports

    RUGGEDCOM i803 Chapter 3 Installation Guide Communication Ports Communication Ports The i803 can be equipped with various types of communication ports to enhance its abilities and performance. To determine which ports are equipped on the device, refer to the factory data file available through ROS. For more information on how to access the factory data file, refer to the ROS User Guide for the i803.
  • Page 18: Fiber Optic Ethernet Ports

    Chapter 3 RUGGEDCOM i803 Communication Ports Installation Guide RJ45 receptacles at either end. Ground loops can cause excessive noise and interference, but more importantly, create a potential shock hazard that can result in serious injury. Each port features a Speed and Link LED that indicates the state of the port.
  • Page 19: Technical Specifications

    RUGGEDCOM i803 Chapter 4 Installation Guide Technical Specifications Technical Specifications The following sections provide important technical specifications related to the device and available modules: • Section 4.1, “Power Supply Specifications” • Section 4.2, “Environmental Specifications” • Section 4.3, “Failsafe Relay Specifications”...
  • Page 20: Copper Ethernet Port Specifications

    To convert from peak to average, subtract 3 dBm. • Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associate when determining maximum segment distances. Fixed Fast Ethernet Transceivers Tx λ...
  • Page 21: Mechanical Specifications

    RUGGEDCOM i803 Chapter 4 Installation Guide Technical Specifications Fixed Gigabit Transceivers Tx λ Power Connector Cable Tx min. Tx max. Rx Sensitivity Rx Saturation Distance Mode (typ.) Budget Type Type (μm) (dBm) (dBm) (dBm) (dBm) (typ.) (km) (nm) (dB) 62.5/125 -9.5...
  • Page 22 RUGGEDCOM i803 Chapter 4 Installation Guide Technical Specifications Mechanical Specifications...
  • Page 23: Dimension Drawings

    RUGGEDCOM i803 Chapter 5 Installation Guide Dimension Drawings Dimension Drawings NOTE All dimensions are in millimeters, unless otherwise stated. 11.7 77.5 95.3 99.5 56.5 Figure 10: Overall Dimensions...
  • Page 24 RUGGEDCOM i803 Chapter 5 Installation Guide Dimension Drawings...
  • Page 25: Certification

    RUGGEDCOM i803 Chapter 6 Installation Guide Certification Certification The i803 device has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. • Section 6.1, “Agency Approvals” • Section 6.2, “FCC Compliance”...
  • Page 26: Industry Canada Compliance

    Chapter 6 RUGGEDCOM i803 Certification Installation Guide this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference on his own expense. Section 6.3 Industry Canada Compliance CAN ICES-3 (A) / NMB-3 (A) Section 6.4...
  • Page 27: Environmental Type Tests

    RUGGEDCOM i803 Chapter 6 Installation Guide Certification Test Description Test Levels Enclosure Air +/- 8 kV C37.90.2 Radiated RFI Enclosure ports 35 V/m C37.90.1 Fast Transient Signal ports +/- 1 kV @ 5 kHz DC Power ports +/- 2 kV @ 5 kHz...