CABINET PREPARATION CUTOUTS
[_ PREPARING THE COUNTERTOP
The countertop must have a deep flat surface to
accommodate the cooktop and the vent. Countertops
with a rolled front edge and backsplash may not provide
the flat surface area required.
25" min. flat surface area required
Clearance between insidefront of cabinet and rear of
countertop cutout must be 20sA"in order to accommodate
cooktop depth.
2sA '' min.
1_" min.
A lh" wide flat area is required around the edge of opening
for support of the unit. The cooktop unit must be level and
sit squarely into countertop opening.
Carefully cut countertop opening according to the
dimensions shown in the illustration. Be sure that opening
is cut squarely,with sides parallel to each other and rear
exactly perpendicular to sides.
20%"
[_ PREPARING
FOR DUCTWORK
NOTE:Ductwork MUSTbe vented to outside. DONOTvent
into a wall, ceiling, crawlspace, attic or any concealed space.
Cut hole in cabinet wall or floor as appropriate for your
installation. Make sure exhaust duct is located between wall
studs or floor joists.
NOTE:When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
183A ''
Rear Wall Venting
Downward
Venting
F_ BLOWERTO DUCTWORKALIGNMENT
In general, the use of flexible ducting is discouraged
because it can cause severelyrestricted airflow. However,
if the blower outlet and the floor or wall duct location do
NOTalign well, then flexible METAL ducting can be used to
adapt to an offset. Good alignment without use of flexible
ducting is best.
NOTE:
• Do not exceed the maximum recommended offset of 6".
• Do not allow the flexible ducting to kink or collapse.
• Do stretch the flexible ducting as much as possible to
eliminate as much of the corrugation as possible.
6" Hax.
t°Ccntni_irl_: e _ i_
/,, Offset
_
Bottom Venting
BackVenting
(Requires 3Y4" x 10")
A 3_4"x !0" rectangle to 6" round transition duct is available
at your local building supply store.
NOTE:Illustrations are for planning purposes only.
!