Ntp-G67 View Alarm Counts On The Lcd For A Node, Slot, Or Port - Cisco ONS 15454 DWDM Installation And Operation Manual

Hide thumbs Also See for ONS 15454 DWDM:
Table of Contents

Advertisement

NTP-G67 View Alarm Counts on the LCD for a Node, Slot, or Port

Figure 7-7
.
Stop. You have completed this procedure.
NTP-G67 View Alarm Counts on the LCD for a Node, Slot, or Port
Purpose
Tools/Equipment
Prerequisite Procedures None
Required/As Needed
Onsite/Remote
Security Level
If you want to view the entire alarm summary for the node, press either the Slot button or Port button
Step 1
on the LCD panel until "Node" appears on the LCD. You will also see the direction, "Status=Alm Ct."
This means that if you press the Status button at this time, as directed in
count for the node.
Press the Status button to see a summary of alarms and severities for the node. You will see a message
Step 2
similar to "Alm CT: 2: MJ:2 MN:2," meaning that there are two critical alarms, two major alarms, and
two minor alarms.
Step 3
If you want to see alarm counts for a particular slot, such as the alarms for an OC-3 card in Slot 2, press
the Slot button until you see "Slot-3" on the LCD. You will see the direction, "Status=Alm Ct."
Cisco ONS 15454 DWDM Installation and Operations Guide, R4.7
7-16
Viewing Alarm-Affected Circuits
Use this procedure to view an alarm summary for a node, slot, or port
without using CTC.
None
As needed
Onsite
None
Chapter 7
Manage Alarms
Step
2, you will see an alarm
November 2004