Setting the display mode
To set the required display mode, press the "SELECT/SET" button.
If you do not press the "SELECT/SET" button for longer than 1 minute, the device
automatically changes to display mode A.
Pressing SELECT/SET button
starting at display mode A
-
Press once
Press twice
Press three times
3.4.6

LEDs "L1" and "L2"

The "L1" and "L2" LEDs indicate the current range of the power supply at connectors L1 and
L2.
The meaning of the "L1" and "L2" LEDs depends on the set display mode, see section
"LEDs "DM1" and "DM2" (Page 30)".
Meaning in display modes A, B and C
In display modes A, B and C, from the "L1" and "L2" LEDs you can see whether the power
supply is higher or lower than 9.6 V.
LED color
-
Green
Meaning in display mode D
In display mode D, the "L1" and "L2" LEDs indicate whether the power supply is monitored.
LED color
-
Green
SCALANCE XC-200
Operating Instructions, 07/2016, C79000-G8976-C442-01
L1/L2 LED
L1/L2 connector
LED status
Off
Power supply lower than 9.6 V
On
Power supply higher than 9.6 V
L1/L2 LED
L1/L2 connector
LED status
Off
Power supply is not monitored.
If the power supply falls below 9.6 V, the signaling contact does
not respond.
On
Power supply is monitored.
If the power supply falls below 9.6 V, the signaling contact re-
sponds.
LED status
DM1
DM2
Off
On
Off
Off
On
On
Description of the device
3.4 LED display
Display mode
Display mode A
Display mode B
Display mode C