Configuring Unit - Lennox XC25-024-230-01 Installation And Service Procedure

Xc25 series
Table of Contents

Advertisement

Configuring Unit

When installing a replacement outdoor control, the unit selection code may have to be manually assigned using the 7-seg­
ment display and push button on the control. The unit code sets unit type, capacity and outdoor fan RPM.
Power-up - Unit selection code (two-digit number) displayed
represents unit size code (outdoor unit capacity).
During initial power-up, firmware version, unit type, unit capacity
and unit selection code will appear on the 7-segment display.
If three horizontal bars are shown in the 7-segment display
during power-up, the outdoor control did not store the last
configuration setting. If this happens, the configuration se­
quence for that setting must be repeated.
To
enter
unit
selection
mode, push and hold the
button next to the 7-segment
display until dash symbol
appears
and
immediately
release button. Once dash
starts flashing, proceed to
next step.
Push and hold button until the solid
PU sequence is displayed on the
7-segment display then immediately
release
the
button.
This
configuration sequence allows the
installer to select unit selection code
(number combination) that matches
the outdoor unit type and inverter.
Press and hold the button during
the PU cycling display.
NOTE - Either the PU sequence
will repeat 5 times and if a
selection is not made the control
will return to idle mode.
SELECTED
If three horizontal bars display in any
part of the 7-segment display string
during
power-up,
the
outdoor
control did not store the unit
selection code. If this occurs, the
configuration sequence for that
section of the display string must be
repeated.
Configuring Unit Selection Code
− −
Outdoor control is in IDLE mode
Yes
(No heating or cooling demand)
_
_
UNIT SELECTION
CODE
U
P
NOT
SELECTED
.
2
3
FIRMWARE
VERSION
Figure 21. Configuring Unit Selection Code
1. When the correct unit section code is displayed, release but­
ton immediately. [Display flashes.]
2. Push and hold button until selection stops flashing during
one of the three cycles. [Release push button]
3. If selection is not made during those three cycles the control
returns to idle mode.
UNIT SELECTION
CODES
2
2-TON HEAT PUMP (XP25-024)
4
3-TON HEAT PUMP (XP25-036)
6
4-TON HEAT PUMP (XP25-048)
7
5-TON HEAT PUMP (XP25-060)
9
2-TON AIR CONDITIONER (XC25-024)
11
3-TON AIR CONDITIONER (XC25-036)
13
4-TON AIR CONDITIONER (XC25-048)
14
5-TON AIR CONDITIONER (XC25-060)
The outdoor control stores the unit type, automatically exits the con­
figuration mode and resets.
EXAMPLE 7-SEGMENT DISPLAY STRING
2
A C
UNIT
UNIT
TYPE
CAPACITY
39
No
Turn room thermostat
to OFF
UNIT
SELECTED
4
1
4
IDLE MODE
UNIT
(NO DEMAND)
CODE
NOT
SELECTED
.
XC25