Power Supply Board Section - Panasonic KX-FG2452CX Service Manual

2.4 ghz cordless phone system with fax and copier
Table of Contents

Advertisement

6.13. Power Supply Board Section

This power supply board uses the switching regulator method.
AC
Input
Input
Circuit
A-B Voltage Wave Form
0
C-D Voltage Wave Form
0
E-F
G-H Voltage Wave Form
0
[Input Circuit]
The input current goes into the input rectifier circuit through the filter circuit. The filter circuit decreases the noise voltage and the
noise electric field strength.
[Rectifier Circuit]
The input current is rectified by D101, D102, D103 and D104 and charges C106 to make DC voltage. Then it supplies power to
the converter circuit.
[Kick-on voltage circuit]
Bias is applied to the Q101 gate via this circuit when the AC power is turned on and Q101 begins operating.
A
Rectifier
+
C106
Circuit
-
D110
B
R104
Kick-on
Voltage
Circuit
Block Diagram
Surge
Absorber
Converter
Circuit
Circuit
C
Q101
Surge
Absorber
D
Circuit
Control
Circuit
IC101
49
G
24V
Output
Circuit
4V
Output
Circuit
E
H
F
Error Detecting
Circuit
KX-FG2452CX
24V
GND
4V
9~6V

Hide quick links: