3-2. CONVERGENCE

Preparation :
Before starting this adjustment, adjust the focus, horizontal size
and vertical size.
Minimize the brightness setting.
Provide dot pattern.
(1) Horizontal and Vertical Static Convergence
Center dot
R
G
B
BMC Magnet
1. (Moving vertically), adjust the V.STAT Magnet so that the red,
green and blue dots are on top of each other at the center of the
screen.
2. (Moving horizontally), adjust the H.STAT VR Magnet so that
the red, green and blue dots are on top of each other at the
center of the screen.
3. If the BMC Magnet cannot bring the red, green and blue dots
together at the center of the screen, adjust the horizontal
convergence with the BMC Magnet and the V. STAT Magnet
in the manner given below.
(In this case, the BMC Magnet and the V. STAT Magnet
influence each other.)
R
G
B
V.STAT Magnet
4. Tilt the V.STAT Magnet and adjust the static convergence by
opening or closing the V.STAT Magnet.
Operation of V.STAT magnet.
If the V.STAT magnet is moved in the direction of the a and b
arrows, the red, green and blue dots move as shown below.
1
a
b
b
2
a
b
3
a
b
b
– 13 –
KV-B14PD1
a
b
B
B
G
G
R
R
a
R
G
B
b
B
G
R
a
b
R
B
G
G
B
RM-883