No.
Error Code
24
E463
25
E464
26
E465
27
E466
28
E467
29
E468
30
E469
31
E470
32
E471
33
E474
34
E475
35
E483
36
E484
37
E485
38
E488
39
E500
40
E554
41
E556
42
E557
43
E590
Samsung Electronics
Meaning
Over current trip / PFC over current error
IPM Over Current(O.C)
Comp. Over load error
DC-Link voltage under/over error
Error due to abnormal rotation of the compressor or uncon-
nected wire of compressor
Error on current sensor (Short or Open)
Error on DC-Link voltage sensor (Short or Open)
Outdoor unit EEPROM Read/Write error (Option)
Outdoor unit EEPROM Read/Write error (H/W)
Error on IPM Heat Sink sensor of inverter 1 (Short or Open)
Error on inverter fan 2
H/W DC_Link Over Voltage Error
PFC Overload (Over current) Error
Error on input current sensor of inverter 1 (Short or Open)
AC Input Voltage Sensor Error
IPM over heat error on inverter 1
Gas leak detected
Error due to mismatching capacity of indoor and outdoor
unit
DPM remote controller option error
Inverter EEPROM CheckSum error
Remarks
Check OLP sensor
IPM
-
Check AC Power and DC Link Voltage
Check Comp wire
Check Outdoor Inverter PBA.
-
Check Outdoor EEPROM Data
Check Outdoor EEPROM PBA
Check Outdoor Inverter PBA.
FAN2 ERROR
Check AC Power
Check Outdoor Inverter PBA.
Check Outdoor Inverter PBA
Check Outdoor Inverter PBA.
Check the refrigerant
Check the indoor and Outdoor unit
Capacity
Check the indoor option code
-