Option
SEG19
Explanation
PAGE
Indication Details Indication Details
Indication
and
3
Details
If you input a number other than 0~4 on the individual control of the indoor unit(SEG 20), the indoor is set as
"Indoor 1".
Example) If you want to set as "Exterior temperature sensor : USE, External control : USE, Number of hours using filer :
2000hr", assign option codes except SEG 1, 7, 13, 19 which are page options.
SEG1
0
SEG7
1
SEG13
2
SEG19
3
1WAY/2WAY/4WAY MODEL : Drain pump(SEG8) will be set to 'USE + 3minute delay' even if the drain pump is set to 0.
1 WAY/2WAY/4WAY,DUCT MODEL : Number of hours using filter(SEG18) will be set to '1000hour' even if the SEG18 is set to
exept for 2 or 6.
4WAY MODEL : Even when the value of Heating setting compensation(SEG21) is set to '0' , it wil be recognized as '5°C' .
4-13
SEG20
SEG21
Individual control of
Heating setting
a remote controller
compensation
0 or 1 Indoor 1
2
Indoor 2
0
3
Indoor 3
1
4
Indoor 4
2
SEG2
SEG3
2
-
SEG8
SEG9
0
-
SEG14
SEG15
1
0
SEG20
SEG21
0
-
SEG22
Disuse
RESERVED
2
5
SEG4
1
SEG10
-
SEG16
-
SEG22
-
SEG23
SEG24
Motion detect
sensor
Indication Details
0.No Use (Factory Setting)
1. Standard Mode/Auto
Set OFF30 Min.
2. Standard Mode/Auto
Set OFF60 Min.
3. Standard Mode/Auto
Set OFF 120 Min.
RESERVED
4. Standard Mode/Auto
Set OFF 180 Min.
5. Premium Mode/Auto
Set OFF30 Min.
6. Premium Mode/Auto
Set OFF60 Min.
7. Premium Mode/Auto
Set OFF 120 Min.
8. Premium Mode/Auto
Set OFF 180 Min.
SEG5
SEG6
0
-
SEG11
SEG12
-
0
SEG17
SEG18
0
6
SEG23
SEG24
-
-