No
Parts
12
Tube Parts
(Assy Tube Suction,
Assy Tube Discharge,
Assy Tube EEV)
13
Heat Excharger
3-22
Procedure
1. Remove the refrigerant surely before pipe
disassembly.
2. Disassemble EEV Coil before work when
you replace EEV.
3. Please weld after wrapping head with a
towel and others so that EEV head is not
heated, when you replace EEV.
1) Loosen 4 bolts fixed to assemble Valve
Service with Bracket Valve.
2) Disassemble the serevel pipe with welding
torch.
Remove the refrigerant surely before Heat
Exchanger.
1) Loosen fixing screw on both sides.
2) Disassemble the pipes in both inlet and
outlet with welding torch.
3) Detach the Heat Exchanger.
Remark