Remove and Replace the Power Supply Module

Do not switch the two SSDs. You MUST install the MSP in slot 2. If you remove it and install it in slot
Caution
1, all stored capture data are lost.
Step 1
Save your configuration.
Step 2
Power down the chassis by moving the power switch to the OFF position. See
on the power switch.
Step 3
To remove the SSD in slot 1, face the front of the chassis, loosen the two captive screws on the SSD, and gently pull it
out of the chassis.
Figure 21: Removing the SSD
Step 4
To replace the SSD in slot 1, make sure the power switch is still in the OFF position, and then hold the SSD in front of
slot 1 and push it in gently until it is seated.
Step 5
To install the MSP SSD, make sure the power switch is still in the OFF position, and then remove the blank faceplate
in Slot 2 by loosening the captive screws on either side of the faceplate.
Step 6
Hold the MSP SSD in front of slot 2 and push it in gently until it is seated.
Do not switch the two SSDs. The MSP MUST be installed in slot 2. If you remove it and install it in slot 1,
Caution
all stored file capture data are lost.
Step 7
Tighten the captive screws on either side of the SSD.
Step 8
Check the SSD LED to make sure the SSD is operative. See
LEDs.

Remove and Replace the Power Supply Module

Take note of the following warnings:
Cisco Firepower 2100 Series Hardware Installation Guide
46
Rear Panel, on page 14
Front Panel LEDs, on page 9
Maintenance and Upgrades
for more information
for a description of the SSD

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Firepower 2110Firepower 2140Firepower 2130

Table of Contents