Alarm In/Out; Protection Diode; Figure 19: Alarm_In/Out Circuit For Gds3710 - Grandstream Networks GDS3710 User Manual

Hemispheric hd ip video door system
Hide thumbs Also See for GDS3710:
Table of Contents

Advertisement

Alarm IN/OUT

Alarm_In could use any 3rd party Sensors (like IR Motion Sensor).
Alarm_Out device could use 3rd party Siren and Strobe Light, or Electric Door Striker, etc.
The figure below shows illustration of the Circuit for Alarm_In and Alarm_Out.
Notes:
The Alarm_In and Alarm_Out circuit for the GDS3710 should meet the following requirement:
Alarm Input
Alarm Output
The Alarm_In circuit, if there is any voltage change between 3V and 15V, as specified in the table
above, the GDS3710 Alarm_In port will detect it and trigger the action and event.
Higher voltage and wrong polarity connection are prohibited because this will damage the devices.

Protection Diode

When connecting the GDS3710 to a door strike it is recommended to set an EMF protection diode in reverse
polarity for a secure use, below examples of deployment for the protection diode.

Figure 19: Alarm_In/Out Circuit for GDS3710

3V<Vin<15V, PINs (1.02KΩ)
125VAC/0.5A, 30VDC/2A, Normal Open, PINs